25
Module Alignment
Frequency Response Adjustment
This adjustment sets the analog video frequency response from
the module input to each A/D converter input. Follow the steps
listed below.
1.
Connect GBR format 100% line sweep to module video
inputs.
2.
Select GBR input format.
3.
Observe response with oscilloscope at TP7 and adjust Y/G
Response C240 to obtain flat response to 5.5MHz.
4.
Observe response at TP12 and adjust B/B-Y Response C340 to
obtain flat response to 5.5MHz.
5.
Observe response at TP16 and adjust R/R-Y Response C401 to
obtain flat response to 5.5Mhz.
NOTE:
If a source of line sweep flat to 6MHz is available response
adjustments should be made to provide flat response to this frequency.
347301A1.book Page 25 Thursday, November 2, 2000 10:41 AM