19
Installation
lists the nominal signal levels for the video formats with
100% saturated color bar signal and 100% luminance.
Y Black Level Control
If the US version of the MII or BETA formats is used, the Y black
level control will be operational. This control compensates for
possible incorrect setup level on the Y video input. The output Y
channel black level will be held fixed by a digital clamp when
using other formats and the control will not function.
Table 2. Signal Levels
Format
Y Channel Level
Peak to Peak
Chroma Level
M
II
(US 525)
647.5mV video
plus 52.5 mV setup
647.5 mV
M
II
(Japan 525)
700mV
700mV
BETA (US 525)
660.4mV video
plus 53.6mV setup
933.3mV
BETA (Japan 525)
714mV
1009mV
EBU N10
700mV
700mV
SMPTE
700mV
700mV
GBR
G, B, and R channels, all 700mV
347301A1.book Page 19 Thursday, November 2, 2000 10:41 AM