GUIDE TO INSTALLATION AND OPERATION
18
| IPG-4901
Status
•
SMPTE 2022-6 Timing To Reference
The ETH1 and ETH2 timings are measured by taking the time difference between reference and the marker bits
in the S2022-6 streams. These values are displayed as values (in
µ
sec).
o
Measurement less than a field in interlaced format and less than ½ frame for progressive format will be
seen as “input is late to Reference ” (positive value).
o
Measurement higher than a field in interlaced format and higher than ½ frame for progressive format will be
seen as “input is early to reference” (negative value)
The timing of both ETH1 and ETH2 ports is reported, in
µ
sec. The range varies with the video format:
SDI Format
Range
525, 1080i59
-16683 to 16680
µ
sec
720p59, 1080p59
−8342 το 8342 µ
sec
625, 1080i50
−20000 το 20000 µ
sec
720p50, 1080p50
−10000 το 10000µ
sec
The measured value is only displayed when the both the reference and the 2022-6 stream are present and
valid; otherwise N/A is displayed.
Selected Reference
SMPTE 2022-6
(SDI I/O Status)
ETH2 Operation
Mode
P. ETH
Input Timing
ETH1
ETH2
Present and valid
Present and valid
OFF
Value
“N/A”
Redundancy
Value
Value
Aggregation
ETH1
Value
“N/A”
ETH2
“N/A”
Value
Any Error
“N/A”
“N/A”
Not present or not valid
“N/A”
“N/A”
•
AES-67 Link Latency
The two windows (ETH1 and ETH2) display the
time difference between RTP timestamps in the AES-67
streams and the system PTP time. Values are shown in
µ
sec.
PTP
ETH2 Operation
Mode
P. ETH
Input Timing
ETH1
ETH2
Present and valid
OFF
Value
“N/A”
Redundancy
Value
Value
Aggregation
ETH1
Value
“N/A”
ETH2
“N/A”
Value
Not present or not valid
“N/A”
“N/A”
.
An
In Range
indicator shows status by color. See the Configuration section below for details.