![GRASS VALLEY HCO-3931 User Manual Download Page 40](http://html1.mh-extra.com/html/grass-valley/hco-3931/hco-3931_user-manual_2257615040.webp)
USER MANUAL
40
| HCO-3931
Property
Description
Automatic
Mode API
Switch Event
Set the behavior when a switchover is triggered through an API-based switching event (RESTfull
Densité command received from a third party system) while the card is in automatic mode.
Switch and enter Manual mode:
Following a switchover caused by an API, the card enters
manual mode.
Switch and remain in Automatic mode:
Following a switchover caused by an API, the card
remains in automatic mode.
Automatic
Mode Inputs
When the card is in the Automatic mode, enable the inputs that can be used by automatic
operation:
MAIN
,
BACKUP
,
EMERGENCY 1
, and
EMERGENCY 2
.
MAIN
and
BACKUP
are always taken into consideration, that is they cannot be ignored by the
rules engine.
You can individually remove
EMERGENCY 1
and
EMERGENCY 2
from the rules engine, so they
will not be considered for an automatic switchover. Any input can still be manually forced.
Bypass
Override for
Emergency
Inputs
When the Bypass mode is activated (3.4.2.2 - Manual switch on page 24), set the behavior for the
card.
Bypass to MAIN:
The input at
MAIN
is sent to the
PGM A
output.
Bypass to best between MAIN and BACKUP:
Either input
MAIN
or
BACKUP
, with the least
impairment, is sent to the
PGM A
output.