3.4.3.3 Video tab
– Black Detect Probe
This error detects the presence of a continuous black signal for a period of time; the probe is triggered when the time
duration criterion and luminence threashold have been satisfied.
Figure 15
Probes panel, Video Tab, Black Detect Probe
Property
Description
Threshold
(mV)
Sets the signal level below which Black will be considered to have been detected.
Set Duration
(sec)
Sets the time interval over which Black must be continuously detected before the error is flagged.
Clear Duration
(sec)
Sets the time interval during which a non-black signal must be continuously detected before a
previously-flagged Black error will be cleared.
See also 3.4.3 - The Probes Panel on page 26 for more information about the configuration parameters.