USER MANUAL
HCO-3931 |
29
3.4.3.1 Video tab
– No Video Probe
The No Video probe detects an absence of video signal on an input for a period of time; the probe is triggered when
the time duration criterion has been satisfied. This probe is always Enabled for
MAIN
and
BACKUP
, and the level set
to
High
,
Low
, or
None
. The factory default value is
High
.
This probe is always Enabled for
MAIN
and
BACKUP
, and the level set to
High
,
Low
, or
None
. The factory default
value is
High
.
Figure 13
Probes panel, Video Tab, No Video Probe
Use the slider to set the duration for which the outage must continuously exist before the probe is triggered. The
nominal range of durations is 0 to 5 seconds.
In AUTO MODE, if switching is not desired when Input
MAIN
changes video format, set the Duration to at least 0.5
seconds
See also 3.4.3 - The Probes Panel on page 26 for more information about the configuration parameters.