8960DEC Instruction Manual
29
Configuration
VBI/Data Line Processing
Use the VBI/Data Processing display shown in
•
Choose the line number for the start of active picture (SAV) from the
Active Picture Start
pulldown selections. (Refer to
for more details if needed). The available data
lines will be displayed.
•
Set
VBI Processing
to
Delete
,
Notch Decode
(low and band pass filtering), or
Video to Luma
(no filtering).
•
Set the Data Line Processing pulldown to either
Notch Decode
(U and V
channels blanked) or
Delete
(remove content), and
•
In 525 line standard, set Data Line Setup pulldown
to
Setup
or
No Setup
.
Refer to the Configuration Summary in
for a summary
of what video lines are affected by each control, all parameters, step sizes,
and default values.
Figure 13. VBI/Data Line Processing Display