This Guide Outlines the Key Functions for a Smooth Operation:
A - Calibrating the CCD Camera White Point using Provided Black Media
B - Calibrating and Adjusting the Cutter’s Position
C - Designing Templates for the F-MARK2
D - iMark Software Overview
A - Calibrating the CCD Camera White Point using Provided Black Media
Chapter 16: How to Calibrate the F-MARK2
(
Starting on page 37)
•
Launch the iMark Software
•
Manually load the black calibration sheet. While loading the sheet note the
positioning using the iMark software camera viewer window screen.
( you should only see the black sheet - nothing else should be seen)
•
Initialize the CE7000 cutter making sure to select Roll 2 on the control panel
( always initialize cutter with Roll 2
)
•
Adjust the blade to the thickness of the material being cut
( use loupe from the accessories kit to make fine adjustments )
Refer to Image A
•
Load the blade holder on tool position one (the slot furthest back)
Refer to Image B
•
Set the recommended
Force Settings
between
9-12
, depending on media.
F-MARK2
Key Functions & Simplified Operation For Smooth Workflow
This quick guide works best when the following has been completed:
• Basic installation of the F-MARK2 unit as outlined in the User’s Manual instructions
• Installation of the latest version of iMark Plus Software available for downloading at:
www.graphtecamerica.com/software
The User’s Manual for the machine & software will guide you through the complete process.
Please note that the Setup User’s Manual also covers a Troubleshooting Section, so in the
event you run into issues, please refer to the manual before contacting Technical Support.
Graphtec also provides helpful Video Training Videos for the
F-MARK2
on our website.
Click on the QR Code below or view the tutorials at
www.graphtecamerica.com/videos
SIMPLIFIED BASIC OPERATION WORKFLOW
The CE7000 will cut a small square. Peel off the square from the sheet.
You should be left with a square cut showing the white liner.
Go back in the iMark Software and click Read Marker.
Once completed, the Delta X should read a value between
90 -120
while the Delta Y box should read a value between
95 - 135
.
Confirm the values by clicking on Set , Then click on the X to Exit,
The X and Y values you input will be saved to the computer .
( If the values are different, repeat calibration. Also, make sure you have sufficient lighting )
NOTE: Camera calibration will need to be performed every time changes occur.
When the computer is shut off, when the F-MARK2 is disconnected from
the USB port or if the software stops communicating.
1
2