background image

 

 

 

PHOTOVOLTAIC MODULES SAFETY 

AND INSTALLATION MANUAL Rev. M 

VALID IN NORTH AMERICA ONLY 

Valid from February 2011 

1305 South Bertelsen Road, Eugene, Oregon 97402, USA 

www.grapesolar.com 

Tel: 1-877-264-1014 (toll free), 1-541-349-9000, Fax: 1-541-343-9000 

 

 

 

 

I.

 

  GENERAL INFORMATION 

1.

 

  Grape Solar photovoltaic (PV) modules are designed to produce DC electrical energy from sunlight.   

2.

 

  This manual contains important safety and installation information of Grape Solar PV modules. All 

safety and installation instructions described in this manual should be thoroughly understood before 
installing, operating and maintaining the PV system.   

3.

 

  Working on a PV system requires specialized knowledge, and must be performed by appropriately 

qualified and authorized personnel only.   

4.

 

  Grape Solar PV modules are subject to operate at ambient temperatures within the range -40°C to 

+85°C (-40°F to +185°F). 

5.

 

  PV modules are intended for outdoor, land-based applications only. 

6.

 

  Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition 

(STC), which is 1000W/m

2

 irradiance, 1.5 Air Mass (AM), and 25°C (77ºF) cell temperature. 

However PV modules can produce voltage at as little as 5% of full sunlight, either connected or not 
connected to an electrical circuit or load.   

7.

 

  Electrical current and power generated by PV module increases with light intensity and higher power 

output than the rated specifications can be achieved at colder temperatures. 

8.

 

  Reflection from snow, water or other surfaces can increase light intensity, and therefore increase the 

current and power generated by the module. 

9.

 

  Do not artificially concentrate light on the module. Concentrating light on the module may result in 

damage to the module and malfunction of the whole PV system. 

10.

 

Follow all safety precautions of other equipments and components used in the PV system. 

11.

 

Retain this manual for future reference. 

12.

 

Grape Solar recommends that the customer makes a note of the serial numbers of modules in order to 
keep a record of the system. 

Summary of Contents for GS-S-150-SF

Page 1: ...ocument applies to Grape Solar photovoltaic modules with model number GS S 150 SF GS S 155 SF GS S 160 SF GS S 165 SF GS S 170 SF GS S 175 SF GS S 180 SF GS S 185 SF Carefully read through this manual...

Page 2: ...ebruary 2011 1305 South Bertelsen Road Eugene Oregon 97402 USA www grapesolar com Tel 1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 2 Table of Contents I General Information 3 II Safety P...

Page 3: ...oor land based applications only 6 Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition STC which is 1000W m2 irradiance 1 5 Air Mass AM and 25 C 77 F cel...

Page 4: ...connected modules have to be stored outside for any length of time always have the glass surface facing down and cover modules with water proof material to prevent water collecting inside the panel a...

Page 5: ...id accidental exposure to live circuits 3 4 When working with modules exposed to light follow all applicable regulations regarding working with live electrical equipment 3 5 Do not install or handle t...

Page 6: ...th or material before making or breaking electrical connections 3 15 Broken junction boxes or broken connectors are electrical and laceration hazardous and cannot be repaired Please contact the instal...

Page 7: ...scal To avoid exceeding the 30 lbs ft2 mechanical loading limit site specific loads such as wind and snow should be taken into account 1 5 The site should not have exposure to extremely corrosive chem...

Page 8: ...nnectors such as MC 4 connectors which are approved for use at the maximum short circuit current of the module 3 7 Over current device e g fuse or circuit breaker whose rating is not greater than the...

Page 9: ...asher and 2 5mm grounding wire A cupped washer is required between grounding wire and the nut with torque less than 4N m Grounding wire should be directly connected with the screw 4 4 The rack must al...

Page 10: ...nt top glass facing downward 5 8 At least a 4 inch clearance between the module frames and structure or wall or ground is required to prevent wiring damage and allows air to circulate behind the modul...

Page 11: ...on 4 Do not remove the dirt by scraping or rubbing away from the module front surface when dry as this may cause micro scratches on the glass and lead to module performance degrading 5 Water can be us...

Page 12: ...damage injury or expense arising through improper use or incorrect installation operation or maintenance Furthermore Grape Solar assumes no responsibility for any infringement of patents or other righ...

Page 13: ...16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 Max System DC Voltage V 600 600 600 600 600 600 600 600 NOCT 50 2 50 2 50 2 50 2 50 2 50 2 50 2 50 2 Current coeff K 0 06 0 01 0 06 0 01 0 0...

Reviews: