PHOTOVOLTAIC MODULES SAFETY 

AND INSTALLATION MANUAL Rev. M 

VALID IN NORTH AMERICA ONLY 

Valid from February 2011 

1305 South Bertelsen Road, Eugene, Oregon 97402, USA 

www.grapesolar.com 

Tel: 1-877-264-1014 (toll free), 1-541-349-9000, Fax: 1-541-343-9000 

 

 

 

11 

IV.  MAINTANIENCE 

1.

   

No routine maintenance is required. 

2.

 

  Grape Solar recommends that periodic inspection of the PV system for tight electrical and mechanical 

connection and free of corrosion should be performed. 

3.

 

  Periodic cleaning of modules is not required, but is recommended, as periodic cleaning can result in 

better performance of the PV system, especially in regions with low levels of annual precipitation. 

4.

 

  Do not remove the dirt by scraping or rubbing away from the module front surface when dry as this 

may cause micro-scratches on the glass and lead to module performance degrading. 

5.

 

  Water can be used for regular washing or rinsing of the module front glass to remove dust, dirt or other 

deposits. 

6.

 

 

To remove ingrained dirt, first rinse off area and let soak for a short period of time (5-minutes). Re-wet 
and use a soft sponge or seamless cloth to wipe glass surface in a circular motion. Mild detergent or 
glass cleaner may be used to clean the ingrained dirt, but harsh cleaning materials such as scouring 
powder, steel wool, scrapers, blades, or other sharp instruments must not be used to clean the module. 
Use of such materials will void the product warranty. 

7.

 

  Always wear rubber gloves for electrical insulation while maintaining, washing or cleaning panels. 

Summary of Contents for GS-S-150-SF

Page 1: ...ocument applies to Grape Solar photovoltaic modules with model number GS S 150 SF GS S 155 SF GS S 160 SF GS S 165 SF GS S 170 SF GS S 175 SF GS S 180 SF GS S 185 SF Carefully read through this manual...

Page 2: ...ebruary 2011 1305 South Bertelsen Road Eugene Oregon 97402 USA www grapesolar com Tel 1 877 264 1014 toll free 1 541 349 9000 Fax 1 541 343 9000 2 Table of Contents I General Information 3 II Safety P...

Page 3: ...oor land based applications only 6 Rated power output specification of Grape Solar PV modules are made at the Standard Test Condition STC which is 1000W m2 irradiance 1 5 Air Mass AM and 25 C 77 F cel...

Page 4: ...connected modules have to be stored outside for any length of time always have the glass surface facing down and cover modules with water proof material to prevent water collecting inside the panel a...

Page 5: ...id accidental exposure to live circuits 3 4 When working with modules exposed to light follow all applicable regulations regarding working with live electrical equipment 3 5 Do not install or handle t...

Page 6: ...th or material before making or breaking electrical connections 3 15 Broken junction boxes or broken connectors are electrical and laceration hazardous and cannot be repaired Please contact the instal...

Page 7: ...scal To avoid exceeding the 30 lbs ft2 mechanical loading limit site specific loads such as wind and snow should be taken into account 1 5 The site should not have exposure to extremely corrosive chem...

Page 8: ...nnectors such as MC 4 connectors which are approved for use at the maximum short circuit current of the module 3 7 Over current device e g fuse or circuit breaker whose rating is not greater than the...

Page 9: ...asher and 2 5mm grounding wire A cupped washer is required between grounding wire and the nut with torque less than 4N m Grounding wire should be directly connected with the screw 4 4 The rack must al...

Page 10: ...nt top glass facing downward 5 8 At least a 4 inch clearance between the module frames and structure or wall or ground is required to prevent wiring damage and allows air to circulate behind the modul...

Page 11: ...on 4 Do not remove the dirt by scraping or rubbing away from the module front surface when dry as this may cause micro scratches on the glass and lead to module performance degrading 5 Water can be us...

Page 12: ...damage injury or expense arising through improper use or incorrect installation operation or maintenance Furthermore Grape Solar assumes no responsibility for any infringement of patents or other righ...

Page 13: ...16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 16 0 35 2 Max System DC Voltage V 600 600 600 600 600 600 600 600 NOCT 50 2 50 2 50 2 50 2 50 2 50 2 50 2 50 2 Current coeff K 0 06 0 01 0 06 0 01 0 0...

Reviews: