For example, the equalize charge voltage for a 12V FLD (Flooded) battery bank is
14.8V*1=14.8V.
The equalizing charge voltage for a 24V FLD (Flooded) battery bank is
14.8V*2=29.6V.
Parameter
Value
Model No.
GS-PWM-20A
Battery System Voltage
12V/24V
Auto (FLDA3EL/5LD) Manual (Li)
No-Load Loss
8ma (12V), 12ma (24V)
Max Solar Input Voltage
<55V
Rated Solar Charge Current
20A
Max Solar Input Power
34OW7I2V
680W/Z4V
Light Control Voltage
5V*n
Light Control Delay Time
10s
Max Load Output Current
20A
Operating Temperature
-35°C - +45°C / -31°F - +113°F
IP Protection
IP32
Net Weight
0.25 kg/0.55 lbs
Operating Altitude
< 3000 meters/< 9842 feet
Controller Dimension
130*90*34.6 mm / 5.11*3.54*1.36 inch
Parameter
Battery Parameters
Battery Types
FLD
SEL
GEL
LI
Equalize Charge Voltage
14.8V*n
14.6V*n
—
—
Boost Charge Voltage
14.6V*n
14.4V*n
14.2V*n
14.4V*n
(adjustable)