3.3 

EXPANSION VESSEL

The expansion vessel should be checked annually, as part of your 

annual service, to ensure that there is a 1.0 bar air charge in the 

vessel. Failure to do this will invalidate the boiler guarantee. Refer 

to Section 1.6 for further details regarding servicing.

! NOTE !

The pressure gauge on the system does not show the air 

charge pressure in the expansion vessel.

! NOTE !

In order to properly care for your Grant boiler, an annual 

service by a compentant person should always be 

undertaken.

3.4 VENTILATION

Your Grant Vortex Outdoor boiler requires a fresh supply of air 

in order for the burner to fire. The boiler draws this air through 

ventilation openings in the bottom boiler casing panel.
These ventilation openings must not be obstructed under any 

circumstances.
You should periodically check that they are clear.
Do not attempt to ‘box in’ the boiler or build a compartment around 

it before contacting your installer.
Do not place any combustible material around or on the boiler or 

flue pipe.

3.5 

FLUE TERMINAL AND CONDENSATE

 DISPOSAL

FLUE TERMINAL

The flue terminal must not be damaged or obstructed in any way.

A wire mesh guard is required to cover the terminal if the terminal 

is less than 2 metres above ground level. If you think one is 

required, contact your installer.
You should periodically check for and remove any obstructions, 

e.g. cut back any bushes that may have grown over the terminal. 

Do not stack anything against or in front of the terminal.
In severe weather conditions, check that the terminal does not 

become blocked by snow or ice.

‘PLUMING’ FROM THE FLUE TERMINAL

Whilst operating, it is quite normal for the boiler to produce a white 

plume of condensation vapour from the flue terminal.
This is due to the high efficiency of the boiler and may be 

particularly evident with low outdoor temperatures.

CONDENSATE DISPOSAL

During the operation of the boiler, condensate is produced from 

the flue gases and this is drained to a suitable disposal point 

through the plastic waste pipe on the left hand side of the boiler.

The condensate drain must not be modified or blocked.
Blockage of the condensate drain, caused by debris or freezing 

can cause automatic shutdown of the boiler. If you suspect 

freezing and the pipe run is accessible, you can try to free the 

obstruction by pouring hot water over the exposed pipe and 

clearing any blockage from the end of the pipe. If this fails to 

remedy the problem, you should contact your service engineer.

3.6 

FROST PROTECTION

All Grant Vortex Outdoor boilers come with with a pre-set 

frost protection thermostat, which operates by sensing the air 

temperature and is designed to protect the boiler and heating 

system during adverse weather conditions. If you are likely to be 

away for a short time, the boiler should be left on so that this frost 

thermostat can function should it need to.
If the boiler is not going to be used for longer periods of time, the 

boiler and system should be drained.

Contact your service engineer for draining and filling the system.

The control panel of the external boiler has a built-in frost 

thermostat, set to operate at 2°C.

! NOTE !

We recommend that both antifreeze and corrosion inhibitor 

be used in the primary water system.

3.7 

FAILURE OF ELECTRICITY SUPPLY

If the electricity supply fails, the boiler will not operate. It should 

relight automatically when the supply is restored.

If a programmer is fitted, it will retain the time settings for up to 24 

hours and will not have to be reset to the correct time of day when 

the supply is restored.
The programmer display will remain for up to 1 hour in the event 

of an electricity supply failure, and will re-appear when the supply 

is restored.

3.8 

CLEANING YOUR BOILER

Lightly wipe over the case with a damp cloth and a little detergent 

and dry completely. 
Do not use abrasive pads or cleaners.
Take care not to touch any hot surfaces.

4  AFTER SALES

 SUPPORT

If your boiler breaks down during the guarantee period, in the first 

instance you should contact your installer to identify the cause of 

the problem and if necessary your installer will contact us. 
If you are unable to contact your installer please telephone the 

Grant UK Service Department for assistance. Authorisation to 

carry out guarantee repairs must be obtained from Grant UK 

before any work is carried out.

Costs incurred by unauthorised work will not be covered by Grant 

UK.
To contact the Grant UK customer support team, please call: 

01380 736920.
If you need to contact Grant UK, please have the following 

information available:

• 

The address at which the installed boiler is located and the 

name of the householder.

• 

Details of the fault and any checks you may have carried out.

• 

Details of the installer and any competant persons who may 

have carried out work on the install in the past (if possible)

Section 3: Caring for your Boiler & Section 4: After Sales Support

Summary of Contents for Vortex Eco Series

Page 1: ...UK DOC 0164 Rev 1 0 January 2020 Grant Vortex Eco Wall Hung External and Wall Hung External System Condensing Oil Boiler Range User Instructions...

Page 2: ...erning likely damage to equipment or tools as a consequence of not following the instructions in the caution NOTE Used for emphasis or information not directly concerned with the surrounding text but...

Page 3: ...If your boiler fails to light 5 2 3 Turning off your boiler 5 2 4 About your fuel 5 2 5 Boiler controls 6 2 6 Heating system controls 6 2 7 Electricity supply 6 3 CARING FOR YOUR BOILER 7 3 1 Checking...

Page 4: ...installer should arrange for this to be carried out If required Grant UK can provide details of OFTEC registered commissioning engineers in your area 1 5 ACTIVATING THE GUARANTEE In order for your boi...

Page 5: ...set to ON 2 Check that the programmer if fitted is working and is set to ON CH or HW 3 Check that all thermostats are set to the desired setting and are calling for heat 4 Check if the burner Lock Ou...

Page 6: ...ammer for further details ROOM THERMOSTAT This thermostat allows you to control the room temperature at which the boiler will fire to provide central heating to your property The room thermostat is us...

Page 7: ...s u r e R a n g e This is the pressure inside the heating system while the system is hot 3 2 HOW TO FILL OR TOP UP YOUR SEALED SYSTEM filling loop Figure 3 2 Sealed system filling loop arrangement To...

Page 8: ...exposed pipe and clearing any blockage from the end of the pipe If this fails to remedy the problem you should contact your service engineer 3 6 FROST PROTECTION All Grant Vortex Outdoor boilers come...

Page 9: ...Signature Service 4 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 5 Date Engineer Company name Telephone number OFTEC Technician number Comments Signa...

Page 10: ...mments Signature Service 12 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 13 Date Engineer Company name Telephone number OFTEC Technician number Commen...

Page 11: ...Page 11 Notes NOTES...

Page 12: ...GRANT ENGINEERING UK LIMITED Hopton House Hopton Industrial Estate Devizes Wiltshire SN10 2EU Tel 44 0 1380 736920 Fax 44 0 1380 736991 Email info grantuk com www grantuk com...

Reviews: