Page 8

Section 3: Caring for your Boiler & Section 4: After Sales Support

4 AFTER 

SALES

 SUPPORT

If your boiler breaks down during the guarantee period, in the 

fi

 rst 

instance you should contact your installer to identify the cause of 

the problem and if necessary your installer will contact us. 
If you are unable to contact your installer please telephone the 

Grant Service Department for assistance. Authorisation to carry 

out guarantee repairs must be obtained from Grant before any 

work is carried out.
Costs incurred by unauthorised work will not be covered by Grant.

To contact the Grant customer support team, please call: 00353 

5791 20089.   
If you need to contact Grant, please have the following information 

available:
• 

The address at which the installed boiler is located and the 

name of the householder.

• 

Details of the fault and any checks you may have carried out.

• 

Details of the installer and any competent persons who may 

have carried out work on the install in the past (if possible)

3.6 

FROST PROTECTION

Your Grant Euro

fl

 ame outdoor boiler does not have a frost 

thermostat 

fi

 tted, but can be added by a register electrical 

engineer if required
If the boiler is not going to be used for longer periods of time, the 

boiler and system should be drained.
Contact your service engineer for draining and 

fi

 lling the system.

! NOTE !

We recommend that both antifreeze and corrosion inhibitor 
be used in the primary water system.

3.7 FAILURE OF ELECTRICITY SUPPLY

If the electricity supply fails, the boiler will not operate. It should 

relight automatically when the supply is restored.
If a programmer is 

fi

 tted, it will retain the time settings for up to 24 

hours and will not have to be reset to the correct time of day when 

the supply is restored.
The programmer display will remain for up to 1 hour in the event 

of an electricity supply failure, and will re-appear when the supply 

is restored.

3.8 

CLEANING YOUR BOILER

Lightly wipe over the case with a damp cloth and a little detergent 

and dry completely. 
Do not use abrasive pads or cleaners.
Take care not to touch any hot surfaces.

Summary of Contents for EFCON5090MOD

Page 1: ...IRL DOC 0021 Rev 02 00 October 2022 Grant Euroflame Condensing External Condensing Oil Boiler Range User Instructions...

Page 2: ...tex Low NOx and Blue Flame boilers DOES NOT comply with ErP requirements or EU regulations and as a result Grant does not condone its use If your boiler uses Bio Kerosene B30K refer to the installatio...

Page 3: ...If your boiler fails to light 5 2 3 Turning o your boiler 5 2 4 About your fuel 5 2 5 Boiler controls 5 2 6 Heating system controls 6 2 7 Electricity supply 6 3 CARING FOR YOUR BOILER 6 3 1 Checking...

Page 4: ...lysis equipment Your installer should arrange for this to be carried out A list of OFFTEC registered commissioning engineers can be found on www oftec org 1 5 ACTIVATING THE GUARANTEE In order for you...

Page 5: ...ure that a fuse has not blown or that the electricity supply has not failed 7 Check to see if the overheat thermostat has operated see Section 2 5 If the burner still fails to light after carrying out...

Page 6: ...radiator As the correct operation of a TRV is based on it sensing the air temperature of the room it is fitted in take care not to cover the TRV head with curtains furniture etc Refer to the manufact...

Page 7: ...harge pressure in the expansion vessel NOTE In order to properly care for your Grant boiler an annual service by a competent person should always be undertaken 3 4 VENTILATION Your Grant Euroflame Con...

Page 8: ...out work on the install in the past if possible 3 6 FROST PROTECTION Your Grant Euroflame outdoor boiler does not have a frost thermostat fitted but can be added by a register electrical engineer if r...

Page 9: ...Signature Service 4 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 5 Date Engineer Company name Telephone number OFTEC Technician number Comments Signa...

Page 10: ...mments Signature Service 12 Date Engineer Company name Telephone number OFTEC Technician number Comments Signature Service 13 Date Engineer Company name Telephone number OFTEC Technician number Commen...

Page 11: ...Page 11 Notes NOTES...

Page 12: ...GRANT ENGINEERING IRELAND ULC Crinkle Birr Co O aly R42 D788 Ireland Tel 353 0 57 91 20089 Email info grantengineering ie www grant eu...

Reviews: