section 2: technical Data
Page 6
2.1 Heat Pump technical Data
table 2-1:
Technical data
model
Unit
HPID12r32
Heating capacity (BS EN 14511 - air: 7°C / water: 35°C)
kW
13.6
COP (BS EN 14511 - air: 7°C / water: 35°C)
5.25
SCOP (average climate conditions) - 35°C
5.93
Heating capacity (BS EN 14511 - air: 7°C / water: 55°C)
kW
11.4
COP (BS EN 14511 - air: 7°C / water: 55°C)
3.23
SCOP - average climate conditions (BS EN 14825 - water: 55°C)
3.97
Power supply
~230V 1ph
50Hz
Power input (BS EN 14511 - air: 7°C / water: 35°C)
kW
2.59
Power input (BS EN 14511 - air: 7°C / water: 55°C)
kW
3.53
Mechanical protection
IPX4
Compressor
DC twin rota-
ry - inverter
driven
Pressure (maximum)
MPa
4.1
Refrigerant
R32
Mass of R32
kg
2.20
Circulating pump
m head
15
Rated air flow (BS EN 14511 - air: 7°C / water: 35°)
m³/h
4,464
Rated air flow (BS EN 14511 - air: 7°C / water: 55°)
m³/h
4,664
Power input of fan (BS EN 14511 - air: 7°C / water: 35°)
kW
-
Power input of fan (BS EN 14511 - air: 7°C / water: 55°)
kW
-
Power input of circulating pump (BS EN 14511 - air: 7°C / water: 35°)
kW
-
Power input of circulating pump (BS EN 14511 - air: 7°C / water: 55°)
kW
-
Flow rate (minimum)
litres/min
15
Rated flow rate (BS EN 14511 - air: 7°C / water: 35°)
litres/min
40.68
Rated flow rate (BS EN 14511 - air: 7°C / water: 55°)
litres/min
40.62
Outdoor temperature
°C
-20 to 43
Maximum inlet water temperature (not operating)
°C
70
Water pressure (system)
MPa (bar)
0.1 to 0.3 (1
to 3 bar)
Sound power level at 1 metre (external)
dB(A)
60.8
Sound pressure level at 1 metre (external) (Q=1)
dB(A)
49.8
Water connections
BSPF
1¼˝
Weight (empty)
kg
99
Weight (full)
kg
101
Water content
litres
2.0
Heat pump casing volume
m³
0.468
ErP rating (low temperature: 35°C flow) - heating
A++ (A+++
from
September
2019)
ErP rating (low temperature: 55°C flow) - heating
HPID12R32
will be
A+++ from
September
2019
2
technical Data
Summary of Contents for Aerona3 HPID12R32
Page 71: ...NOTES Notes Page 71...