Operating instruction  Granit N2000 / N2000C

in connection with SAFETY HINTS ELECTRIC FENCER

Installation and connection:  

The installation is to be made at a location protected from weather and where there is no risk of fire. 
The energizer must be mounted in a vertical position. 
The earth stake must be inserted into the ground as deep as possible at a moist place and connected 
to the earth terminal  

 on the energizer. 

Connect the fence connection cable to the fence terminal ( 

 or   ).

To prevent damages by lightnings the connection lead to the building, prior to entering the buil-
ding, must have a grounded lightning gap.

Operation and control N2000:

  

Plug the mains cable in a 230 V supply socket. After a few seconds a slight tic-tac can be heard. The 
control lamp flashes with the pulses and the energizer operates properly. If this lamp is not illuminated 
the energizer or the fence system is faulty.

Operation and control N2000C:

Plug the mains cable in a 230 V supply socket. After a few seconds a slight tic-tac can be heard. The 
fence voltage level flashes with the pulses. The 8 controll lamps indicate the fence voltage. 
At least 3 lamps should flash to ensure sufficient voltage and fencing. 
Possible reasons, when the voltage is too low:
a) with fence:      heavy vegetation on the fence, insulator flash-over or fence too long. 
b) without fence:  the energizer is faulty, see service.

The energizer has two fence terminals 

 (Z1)  = max output    (Z2) = reduced output

Both outlets can operate separate fences at the same time. A short in the  Z2 fence has no strong 
influence on Z1 but a short or a deviation in Z1 means a further reduction of Z2.
By operating with two fence systems ( Z1 + Z2 ) the indication lamps show the reduced output only.

Earthing:

 

For a faultless operation and to obtain best possible output a good grounding  is very important. There-
fore the grounding must be made at a rather moist and overgrown place. 
3 or 4 pcs of 1 m earth stakes shall be used. With long fences and on dry soil a ground return wire with 
intermediate groundings (every 50 m) is necessary. The distance between the system earth and the 
protective and system earth of the supply net work shall be at least 10 m.

Service:

  

Servicing is only to be made by qualified service personell. Only by the manufacturer com-
manded replacement parts must be used. If the supply cord of this energizer is damaged this 
cord must be replaced by a special supply cord which is recommended by the manufacturer. 

SUBJECT TO TECHNICAL ALTERATIONS !

en

Summary of Contents for N2000C

Page 1: ...de Cl ture fr ISTRUZIONI PER L USO Recinto Elettrico it INSTRUCCIONES DE USO Cercado Electrico Accionado es 85106G A 06 13 Wilhelm Fricke GmbH Zum Kreuzkamp 7 D 27404 Heeslingen Tel 49 4281 712 712 Fa...

Page 2: ...ng Mains supply Cordon secteur Cavo di rete Cable el ctrico 230V Art Nr 88707 ERDE EARTH TERRE TERRA TIERRA ZAUN FENCE CL TURE RECINTO CERCA Granit N2000C Leiterplatte sek 8 Glimmlampe Platine 8 lampe...

Page 3: ...cherheit sollten min 3 Lampen aufleuchten andernfalls ist die Spannung zu gering M gliche Ursachen a mit Zaun starker Bewuchs am Zaun schlechte Isolatoren Kurzschluss an Metallpf hlen oder Zaun zu lan...

Page 4: ...d flash to ensure sufficient voltage and fencing Possible reasons when the voltage is too low a with fence heavy vegetation on the fence insulator flash over or fence too long b without fence the ener...

Page 5: ...rrectement forte charge beaucoup de v g tation isolateur d fectueux cl ture trop longue b Si la cl ture ne fonctionne pas correctement e poste de cl ture est d fectueux le faire r parer par une person...

Page 6: ...ado Posibles razones si el voltaje es bajo a con vallado mucha vegetaci n en el vallado aisladores o vallado demasiado largo b sin vallado el pastor el ctrico falla Ver servicio El pastor tiene dos te...

Page 7: ...rtare la tensione e la recinzione sufficienti Cause possibili quando la tensione troppo bassa a con recinzione la vegetazione provoca dispersione dalla recinzione o recinzione troppo lunga b senza rec...

Page 8: ...a massima recinto Technische Daten technical data donn es techniques datos t cnicos dati tecnici Granit N2000Art Nr 580580108 230V AC 50 Hz 3 W 2 Joule Granit N2000C Art Nr 580236 230V AC 50 Hz 3 W 2...

Reviews: