8. Reading and saving EDID data from display
Before perform reading and saving EDID data from display, please make sure which output is the
EDID from and which input is the destination the EDId will be copied to. The detailed procedures
are as below:
1)
Choose the output port where the EDID will be copied from (Assumed as OUTPUT_N), and input port
where the EDID will be copied to (Assumed as INPUT_N). Control the matrix to connect them.
2)
Under MX0808-311’s normal working condition, push ‘ENTER’ and ‘OUTPUT_N’ simultaneously, within
two seconds will see the LEDs lit the character ‘-‘ circularly(Means the EDID COPY is auto running). Just
release the buttons, waiting for the matrix to finish the operation.
3)
If the EDID COPY succeeds, then the LED will show MIX OK. Otherwise the Leeds will display MIX FL.
Push the ‘ENTER’ button or wait for 3 seconds. MX0808-311 goes into normal working condition.
For example
:
Copy the EDID from the display connected to OUTPUT1 to INPUT8.
1. Connect the display to OUTPUT1 of MX0808-311. Power on MX0808-311 and the display.
2. Switch the matrix to connect OUTPUT1 to INPUT8.