Grand Effects
360 Fire-Water Bowls and Fire-Water Inserts (Automated Operation)
Operating and Maintenance Instructions
4. Control panel should be installed at higher elevation than the water bowl.
5. Maintain good piping practice by keeping pipe length and elbows to a minimum
to eliminate unnecessary pressure drops. Corrugated flex gas lines should not be
used.
6. On commercial installations, it is recommended to install a keyed switch and kill
switch located in close proximity and in visible sight of feature or features. The
keyed and kill switches are supplied by Grand Effects.
7. Gas, electrical, and drain connections must be located to fit in a 6” sleeve. Make
the area around connections water tight as shown in Figure 4. Elbows need to be
installed on gas, electrical, and drain connections for hoses to be positioned
properly as shown in Figure 4.
Note:
Control panel should be installed at higher elevation than fire-water
feature.
Figure 4: Gas/Electrical and Drain Connections
8. Connect gas hose to the burner assembly.
9. Install wire nuts on wires from the control panel and burner assembly. Be careful
to hook up the “positive” to the “positive” and the “negative” to the “negative.”
Wrap wire nuts with electrical tape or some means to prevent moisture from
getting in. Make sure wire nuts are positioned at the bottom of the bowl, away
from the bottom of the burner assembly.
www.grandeffectsinc.com
949-697-5270
4