![GRAND EFFECTS 42](http://html.mh-extra.com/html/grand-effects/42-biltmore/42-biltmore_operating-and-maintenance-intructions_2254975005.webp)
Grand Effects
360 Fire-Water Bowls and Fire-Water Inserts (Automated Operation)
Operating and Maintenance Instructions
Figure 2: Propane Gas
Figure 3: Commercial Installation
3.
Install low voltage wiring (14 or the 16 ga. 12VAC) underground between the
control panel and the 360 fire-water bowl. Wire per Grand Effects wiring diagram.
120v source into the control panel can come from any 120v source, including
auxiliary relay from the pool controller or home system. Typically, the pool
controller is the device that turns the unit on and off. If a pool controller is not
available, Grand Effects can provide a hand-held remote system,
or an
electrician can wire a decorative switch for on/off control up stream of the Grand
Effects control panel.
www.grandeffectsinc.com
949-697-5270
3
12 VAC
12 VAC
12 VAC
12 VAC
12 VAC
12 VAC