background image

12

GrandCanyonGasLogs.com 

[email protected]

TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

1. Pilot will not light

  a  Obstruction in pilot gas supply or  

    pilot gas-supply line is kinked

  b. Inadequate gas pressure

  c. Air in line

  a. Clear out obstruction.  

    Replace pilot gas-supply line if  

    kinked

  b. Have gas pressure checked by

    installer or gas supplier

  c. Air should clear; attempt to relight

2. Pilot will not stay lit

  a. Loose wires

  b. Low gas pressure

  c. Faulty thermopile

  d. Safety magnet wire not connected  

    on TH TP terminal

  a. Check all wires are securely in  

    place

  b. Check gas pressure

  c. Check MV voltage

  d. Connect safety magnet wire to  

    TH TP terminal

3. Pilot lights, but main

  burner will not

  a. Wire leads are not connected to

    proper valve terminals

  b. Defective valve

  a. Make sure all wire leads are tight  

    and attached to proper terminals  

    (see wiring diagram section pg 4)

  b. Check valve using service 

    instructions component check &  

    valve operator system

  c. Replace valve

4. Burner system not burning

  properly

  a. Low flame/uneven flame 

  a. Check for low gas pressure;  

    should have operating pressures  

    of 5" w.c. for natural gas, 11" w.c.  

    for propane at manifold

 

5. Burner system shuts

  down during operation

  a. Glass doors closed, causing

    excessive heat buildup

  b. Thermopile is dirty or damaged

  c. Heat shield not in place

  a. Always run fireplace with 

    doors fully opened

  b. See INSTALL (page 6-8)

  c. Clean with brass brush and check  

    for Millivolt dropout. Replace if  

    Millivolt levels drop out.

Periodically inspect the pilot assembly and valve controls and maintain them free of obstruction or debris. If the pilot flame is 

not blue with possibly yellow tips and does not impinge on the electrodes or if the pilot does not stay lit, contact a qualified 

professional service technician to service the pilot system.

Summary of Contents for HCMVQMKLP

Page 1: ...fireplace where the unit is installed The installation including provisions for combustion ventilation air and required minimum permanent vent opening must conform with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and applicable local building codes In Canada the installation must conform with the Natural Gas and Propane Storage and Handling Installation Code CSA B 149 1 A damper stop clamp is i...

Page 2: ...tion 5 Installation 6 L P Gas Applications 8 Procedure for Lighting or Relighting 9 Service Instructions 10 Troubleshooting 12 Warranty 13 NOTE Changes may change without notice Changes will be shown on updated versions TABLE OF CONTENTS SPECIFICATIONS Refer to the burner owner s manual for minimum firebox dimensions Model BTUs N G L P 370 000 560 000 HCMVQM MAX BTU OUTPUT ...

Page 3: ...EM WITH THE GLASS DOORS FULLY OPEN BOTH SIDES IF THE FIREPLACE IS A SEE THROUGH TYPE This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes Installation of appliances designed for manufactured homes or mobile homes must conform with Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the U S or wit...

Page 4: ...mbly NG version 1 2A MV PILOT 18P 18 Millivolt Pilot Assembly LP version 1 3 US 4 8 1 2 x 1 2 Swivel Nut Union 1 4 46 88 Straight Connector 1 2 OD x 1 2 FIB 2 5 Heat Shield HC Millivolt Heat Shield 1 6 Reducer 3 2 3 4 to 1 2 Reducer 2 7 B5309 8 90º Elbow 1 2 2 8 113BS D Schedule 40 1 2 MIP Closed 1 9 1751 016 700 Series LP Conversion Kit LP Model only 1 3 2 1 5 4 6 7 8 ...

Page 5: ...4 GrandCanyonGasLogs com customerservice grandcanyongaslogs com WIRE DIAGRAM MILLIVOLT ...

Page 6: ...mum 10 W C Propane This Millivolt Control must be installed by a qualified professional service technician Instructions must be followed carefully when installing to ensure proper performance These instructions must be used as a supplement to the instructions supplied with the Grand Canyon Gas Logs burner system Follow the burner system instructions and make adjustments as appropriate for the addi...

Page 7: ...NSTALLATION Leave the first two threads clean Never use compound on female threads as it might be pushed into the control body 6 The gas valve is multi position and can be mounted in any position except upside down without effecting its operation 7 Install gas valve so gas flow conforms with the inlet and outlet of the control 8 DO NOT insert any object other than suitable pipe or tubing in the in...

Page 8: ...rom you Then install the other 48 88 into the B5309 8 and wrench until tight For ALL 2 Burners Glass Burners Kiva Burners front view and see through the 48 88 should point back towards the IN of the valve Fig 1 For 3 Burners and Jumbo Jumbo Slimline Burners front view and see through the 48 88 should be pointing up at a 45 degree angle Fig 2 Locate the US 4 8 1 2 x 1 2 flared swivel nut union fitt...

Page 9: ... address and phone number DO NOT go back into the building If help is coming wait for them to arrive If L P tank runs out of fuel turn off gas appliance After L P tank is refilled appliance must be relit according to manufac turer s instructions If the gas control has been exposed to WATER in any way DO NOT try to use it It must be re placed DO NOT attempt repair on gas valve or appliance Tamperin...

Page 10: ...r explosion may result causing property damage personal injury or loss of life LIGHTING INSTRUCTIONS FOR MILLIVOLT VALVE 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 3 Wait five 5 minutes to clear out any gas If you smell gas STOP Follo...

Page 11: ...ified for the system being checked clean and tighten thermo stat leads and connections shorten leads wires if possi ble or use heavier gauge wire Rapidly cycle thermostat to clean contacts or change the thermostat PROCEDURE FOR LIGHTING OR RELIGHTING Dials must be operated by hand DO NOT use pliers wrenches or other tools to turn dials The Gas Cock Dial has a dual function A Complete control of ga...

Page 12: ... 1 Remove regulator adjustment screw cap Top of regulator 2 With small flathead screwdriver rotate adjustment screw clockwise to increase or counterclockwise to decrease pressure 3 Replace regulator adjustment screw cap REGULATOR CONVERSION OR REPLACEMENT CAUTION Main burner and pilot orifices must be changed when regulator is converted from one type of gas to another REGULATOR REPLACEMENT If it i...

Page 13: ...leads are tight and attached to proper terminals see wiring diagram section pg 4 b Check valve using service instructions component check valve operator system c Replace valve 4 Burner system not burning properly a Low flame uneven flame a Check for low gas pressure should have operating pressures of 5 w c for natural gas 11 w c for propane at manifold 5 Burner system shuts down during operation a...

Page 14: ...ginal purchaser only Indoor burners installed outside carry a 1 year warranty Electrical and Valves Grand Canyon Gas Logs valves remotes receivers carry a 2 year warranty against breakage or defects from date of purchase by original purchaser and must be installed be a licensed profes sional installer This warranty only covers use with Grand Canyon Gas Logs burners and logs In the event a defect o...

Page 15: ...ALL US FIRST For immediate help with installation product information or if your product arrives damaged please call our toll free number at 1 602 344 4217 Monday Friday 8 00AM 5 00PM AZ Mountain Time or email us at customerservice grandcanyongaslogs com OUR STAFF IS READY TO PROVIDE ASSISTANCE ...

Page 16: ...of enjoyment of our products Take a look at our other products from our RPG Brands family of companies Copyright 2022 RPG Brands Grand Canyon Gas Logs All rights reserved Products and specifications subject to change without notice The product images shown are for illustration purposes only and may not be an exact representation of the product ...

Reviews: