5
440 02 7000 02
Specifications subject to change without notice.
6. The burner flames are in good adjustment, Figure 5 (by
comparison with pictorial sketches or drawings of the main
burner flame).
Figure 5
Burner flame adjustment
STARTING YOUR FURNACE
Your furnace uses an automatic, hot surface ignition system to light
the burners each time the thermostat signals the furnace to start.
Follow these important safeguards:
S
Never attempt to manually light the burners with a match
or other source of flame (Figure 6).
Figure 6
Do Not Light Burner with Match
S
Read and follow the operating instructions on inside of
main furnace door, especially the item that reads as
follows:
“Wait 5 minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas,
STOP!
Follow “B” in the safety information on furnace label. If
you don’t smell gas, go to the next step.”
S
If a suspected malfunction occurs with your gas control
system, such as the burners do not light when they
should, refer to the shutdown procedures on inside of
main furnace door, or in the “Shutting Down Your
Furnace” section and call your dealer as soon as possible.
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,
death or property damage.
Should the gas supply fail to shut off or if overheating occurs,
turn off the manual gas valve to the furnace BEFORE turning
off the electrical supply and install lockout tag.
!
WARNING
S
CHECK AIR FILTER:
Before attempting to start your
furnace, be sure the furnace filter is clean and in place.
See “Performing Routine Maintenance” section in this
manual. Do not run the furnace without a filter in place.
Then proceed as follows:
STEPS FOR STARTING YOUR FURNACE
1. Set your room thermostat to the lowest temperature setting
(Figure 7).
Figure 7
Lowest Temperature Setting
2. Close the external manual gas valve (Figure 8).
Figure 8
Close Valve
CLO
S
E
3. Turn OFF electrical supply to the furnace (Figure 9).
Figure 9
Turn Off Electrical Supply
4. Remove the main furnace door (Figure 10).
Figure 10
Remove Furnace Door
5. Turn the control switch on the gas control to the OFF position
and wait 5 minutes. See Figure 11. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow “B”
on furnace label. If you don’t smell gas, go to next step.