ELECTRICAL
Wire according to the National Electrical Code (Canadian Electrical
Code in Canada) or local codes. Use a separately fused #12 electrical
line directly from the service panel to the furnace junction box. Install a
manual shut-off switch at the door or stairway to furnace room so
furnace can be shut off remotely.
The furnace must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, and/or the Canadian Electrical Code , CSA
C22.1, Part 1, if an external electrical source is utilized
The wiring shall conform with the temperature limitations of 63°F
(35°C) rise.
The furnace shall be installed so the electrical components are
protected from water.
CLEARANCES
Before placing unit, review installation clearances as shown on furnace
operating decal or section PRODUCT INFORMATIONS.
LOCATION
Install the furnace close to chimney and central to ductwork.