![Gram 866100635 Operating Manual Download Page 5](http://html1.mh-extra.com/html/gram/866100635/866100635_operating-manual_2254506005.webp)
- 5 -
765041559
Rev. 002
Error codes in the display
Display code
Description
- o -
The door is open
A1
Door alarm ”dAd” from LAL and/or EAL has been activated
A2
Local upper alarm LHL is or has been avtivated
A4
External upper alarm EHL is or has been activated
F1
Cabinet sensor error.
In the meantime the cabinet itself will maintain the set
temperature by the memory of the controller
. Temperature stability will be affected.
Service assistance is required.
F2
Evaporator sensor error. Service assistance is required.
The cabinet will keep running until the error has been mended.
F3
Condenser sensor error. The cabinet will keep running, until the error has been mended.
Service assistance is required.
F7
Indicates that the condenser temperature is too high. The cause might be a clogged
condenser, or too high ambient temperature.
If the condenser or air filter needs cleaning, the cabinet must be disconnected at the
mains power. Cleaning of the condenser is done with a brush or a vacuum cleaner.
The air filter can be removed and cleaned in a dishwasher at max. 50
C.
If the ambient temperature is too high, the placement of the cabinet might be wrong,
and an alternative place should be found. Ventilation might help.
If this does not help, request service assistance.