4. OPERATION
PRE-START CHECKLIST:
1.
Check oil level. Add if necessary.
2.
Remove any moisture in the air compressor air tank. Remove excessive pressure with an air tool, then open the
air tank drain valve in the bottom of the air tank. Close tightly when drained.
WARNING: Risk of bodily injury. NEVER attempt to open the drain valve when more than 10 PSI of
air pressure is in the air tank!
3.
Make sure the air compressor Motor Switch is in the “OFF” position.
4.
Make sure all safety valves are working correctly.
5.
Make sure all guards and covers are in place and securely mounted.
START-UP
Read safety warnings before performing operation.
1.
Ensure the lever on the pressure switch box is in the “OFF” position.
2.
Plug the power cord into a grounded outlet.
3.
Move the lever on the pressure switch box to the “AUTO” position.
4.
Set pressure by adjusting the pressure regulator knob counterclockwise for less pressure and clockwise for
more pressure.
5.
If you notice any unusual noise or vibration, stop the air compressor and refer to “Troubleshooting”.
SHUTDOWN
1.
To stop the air compressor, move the lever on the pressure switch box to the “OFF” position. NEVER stop the
air compressor by unplugging it from the power source. This could result in risk of electrocution.
2.
Drain air from the air tanks by releasing air with an attached air tool or by pulling on the safety relief valve ring.
3.
Once pressure in the air tanks register under 10 pounds, open the drain valve under each air tank to drain any
moisture.
4.
Allow the air compressor to cool down.
5.
Wipe air compressor clean and store in a safe, warm area.