3.
Description
The system controls offer an easy to use guide for the switch programming. Using an LCD
display the fill measurement is shown in 1 % stages (in relation to the height of the
tank).The sensor operates with a 12 volt supply. All programmed values such as
the tank
height are retained after disconnection of the power supply or after a power-cut.
Performance features:
–
Fill level measurement readout in 1% steps and with an additional bar type indicator
–
In 1% steps freely variable choice of the switching points for the drinking water refill
–
Automatic flushing of the system (choice of intervals in day and time are possible)
–
Dialogue oriented user guidance (choice of language)
–
Equipment indication using 3 additional LED
–
Supervision of the measurement pick-up and the sensor
–
Error indication in simple text
Technical data:
Control electronics
Measurement sensors
Operating voltage
: 230V AC
Measurement voltage
: 12V DC
Fused
: 50mA slow-blow
Measurement frequency
: (0,2-20)kHz
Power consumption : 3VA
Data cable length
: 20m
(max. 50m)
Tank height
: 3m
(optional 6m)
Measurements [mm] : 155x165x90
Measurements [mm]
: 90x80x50
Pump connection
Valve connection
Operating voltage
: 230V AC
Operating voltage
: 230V AC
Pump capacity
: max. 1200VA
Output current
: max. 1A
Only the control electronics in the device are protected by the fuse. Valves and
pump connections are
not
protected. These are protected only by the mains sup-
ply via the mains fuse.
9
Summary of Contents for 351021
Page 27: ...Space for your notes 27 ...