Shutdown
311164M
17
Shutdown
1.
Follow
, page 13.
2.
Remove tip and tip guard from gun.
3.
Engage gun trigger lock.
4.
Place siphon tube in grounded metal pail containing
cleaning fluid.
5.
Open bleed type master air valve (B). Turn regulator
adjustment knob (G) counterclockwise to lowest
possible fluid pressure.
6.
Hold a metal part of the gun firmly to a grounded
metal pail. Trigger the gun until clean solvent dis-
penses.
7.
CAUTION
Never leave water or water-base fluid in pump over-
night. If you are pumping water-base fluid, flush with
water first, then with a rust inhibitor, such as mineral
spirits solvent (also called white spirit). Relieve pres-
sure, but leave rust inhibitor in pump to protect parts
from corrosion.
TI5049a
G
-
B
TI8727a