Performance Charts
24
3A3381E
Performance Charts
To find Fluid Outlet Pressure (psi/MPa/bar) at a spe-
cific fluid flow (lpm/gpm) and operating hydraulic pres-
sure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected
fluid outlet pressure curve (black). Follow left to
scale to read fluid outlet pressure.
To find Motor Hydraulic Oil Consumption (l/min. or
gpm) at a specific fluid flow (l/min. or gpm):
1.
Locate desired flow along bottom of chart.
2.
Read vertical line up to intersection with hydraulic oil
consumption curve (dashes). Follow right to scale to
read hydraulic oil consumption.
See Models on page 3 for your pump part number.
Viscount I Plus Motor, 750cc Lower
Viscount I Plus Motor, 1000cc Lower
PU
M
P OU
T
L
ET
P
R
ES
S
U
R
E
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
HYDRAULIC OIL
CONSUMPTION
psi (MPa, bar)
0
3
(11)
12
(46)
15
(57)
6
(23)
9
(34)
0
5 (19.0)
3 (11.4)
1 (3.8)
B
CPM
A
C
4 (15.2)
2 (7.6)
19
37
56
74
500
3.4, 34)
200
(1.4, 14)
400
(2.8, 28)
100
(0.7, 7)
300
2.1, 21)
GPM
(l/min)
GPM
(l/min)
Key:
A
10.3 MPa, 103 bar (1500 psi)
hydraulic pressure
B
7.2 MPa, 72.4 bar (1050 psi)
hydraulic pressure
C
4.1 MPa, 41 bar (600 psi)
hydraulic pressure
The shaded area within the
table shows the recommended
range for continuous duty circu-
lation applications.
PUMP O
UTLET
PRESSURE
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
HYDRAULIC OIL
CONS
UMPTION
Summary of Contents for Viscount 17E230