Flushing
When to flush
Determine material to spray from column 1. Flush with
material in column 2. Then follow recommendations in
one of next three columns.
CAUTION
Do not leave water or water-based fluids in sprayer if
it could freeze. Push water out with mineral spirits.
Frozen fluid in sprayer prevents starting and may
cause serious damage.
If you are going to:
Flush with:
Prime with:
Clean with:
Store unit with:
Spray with new sprayer or
sprayer that has been
stored
Mineral spirits, then
compatible solvent
such as water or
mineral spirits
Compatible paint,
such as latex or
oil-base
Compatible solvent
such as water or
mineral spirits
Mineral spirits
Spray latex paint
Warm, soapy water,
then clean water
Latex paint
Warm soapy water,
then clean water
Mineral spirits
Spray oil paint
Mineral spirits
Oil-base paint
Mineral spirits
Mineral spirits
Change latex to oil paint
Warm, soapy water,
then clean water
Mineral spirits
Mineral spirits
Mineral spirits
Change oil to latex paint
Mineral spirits, then
soapy water, and fi-
nally, clean water
Latex
Warm, soapy water,
then clean water
Mineral spirits
Change colors, same base
Compatible solvent
such as water or
mineral spirits
How to flush
WARNING
FIRE AND EXPLOSION HAZARD
To reduce static sparking and splashing,
always remove the spray tip from the
gun, and hold a metal part of the gun
firmly to the side of a grounded metal pail when
flushing.
1.
Follow
Pressure Relief Procedure
on page 7.
Engage gun safety latch.
2.
Turn pressure adjusting knob (J) fully counter-
clockwise to zero pressure.
3.
Remove spray tip from gun. See Fig. 8. Remove
filter bowl, filter support and screen. Clean screen
separately and install bowl without screen or
support to flush it.
4.
Put suction tube into a grounded metal pail with
1/2 gallon of compatible solvent. Close pressure
drain valve (G).
5.
Start sprayer. See page 7. To save fluid still in
sprayer, trigger gun into another container until
next fluid appears, then trigger gun back into fluid
compatible solvent container. Circulate flushing
fluid a few minutes to thoroughly clean system.
6.
Do not run pump dry for more than 30 seconds to
avoid damaging pump packings!
7.
Follow
Pressure Relief Procedure
on page 7.
Engage gun safety latch.
8.
Unscrew filter bowl and reinstall clean screen.
Install bowl and hand tighten.
9.
Remove suction tube and screen and clean them
separately.
G
FILTER
BOWL
SCREEN
FILTER
SUPPORT
Fig. 8
J