Torch and Screed Burners Gas Regulator Replacement (ThermoLazer 300TC/ProMelt)
28
3A1320L
Torch and Screed Burners Gas Regulator Replacement
(ThermoLazer 300
TC
/ProMelt)
Removal
1. Close manual gas shut-off valve on propane tank.
2. Disconnect gas supply hose from propane tank.
3. Disconnect gas line at downstream tube elbows
(161).
4. Unscrew swivel union (323) from upstream pipe
elbow (142).
5. Unscrew gas regulator (152) from fitting (323).
6. Unscrew and remove gas regulator (152) from
upstream pipe elbow (142).
Installation
1. Apply pipe sealant to downstream pipe tee (12).
Screw pipe tee (12) with elbow (161) to gas regula-
tor (152). Turn connection until gas tight.
2. Apply pipe sealant to fitting (323) and screw into gas
regulator (152). Turn connection until gas tight.
NOTE:
Make sure IN connection of regulator is con-
nected to fitting (323).
See FIG. 7
3. Screw swivel union (323) onto upstream pipe elbow
(142); which is now connected to gas regulator
(152). Turn connection until gas tight.
NOTE:
Make sure IN connection of regulator is con-
nected to the upstream pipe elbow (142).
See FIG.
7
4. Connect gas line at downstream tube elbows (161).
Turn connection until gas tight.
5. Connect gas supply hose to propane tank.
6. Open manual gas shut-off valve on propane tank.
7. Check gas lines for gas leaks (see
Operation
man-
ual).
ti14128a
ti14411a
ti14127a
FIG. 7
ti25753a
323
142
12
152
161
161
OUT
IN
323
152
12
OUT
IN
Arrow
Indicates
Direction
of Gas
Flow
ti24821a