309213G

EN

Instructions-Parts List

Therm-O-Flow

Accessory Heat Zone Controls

Maximum Operating Temperature All Models 400°F (204°C)

2-zone Accessory Control (243698) 
4-zone Accessory Control (243699)

Refer to Graco form 309180, Installation and 
Operation Guide for installation and operation 
instructions.

Important Safety Instructions

Read all warnings and instructions in this 
manual. Save these instructions. 

4-Zone Accessory Control - 243699

TI0561

2-Zone Accessory Control - 243698

TI0562

GRACO INC.     P

.

O

.

 BOX 1441     MINNEAPOLIS

,

 MN     5544D

 1441

Copyright 2000, Graco Inc

.

 is registered to I.S

.

 EN ISO 9001

 

See page 2 for Table of Contents.

Summary of Contents for Therm-O-Flow 243698

Page 1: ...orm 309180 Installation and Operation Guide for installation and operation instructions Important Safety Instructions Read all warnings and instructions in this manual Save these instructions 4 Zone A...

Page 2: ...the True Earth Ground 9 Checking Resistance 9 Overview of the Temperature Controller Settings11 Graco Factory P I and d Settings 11 Operation 12 Reading the Temperature Controllers 12 Temperature Out...

Page 3: ...ed power source All electrical wiring must be done by a qualified electrician and comply with all local codes and regula tions TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injur...

Page 4: ...hout tip guard and trigger guard installed Engage trigger lock when not spraying Follow Pressure Relief Procedure in this manual when you stop spraying and before cleaning checking or servicing the eq...

Page 5: ...long fluid run from the unloader to the dispense point An acces sory 2 or 4 zone control can be added to the system to heat additional zones beyond the six of the system unloader Typical Installation...

Page 6: ...it material hoses that are rated at a maximum of 1250 watts and single circuit devices rated at a maximum of 500 watts The 243698 2 zone control can control a 25 foot Therm O Flow hose 1250 watts max...

Page 7: ...tructions Object Material is Applied to Ground the object according to your local code Material Drums Ground the material drums according to your local code Use only metal drums placed on a grounded s...

Page 8: ...ire from the power source into the con trol panel housing and then connect the power source wires to the appropriate terminals on the panel See Electrical Schematics beginning on page page 19 WARNING...

Page 9: ...the sensor resistance 1 Make sure the power is off and that the disconnect switch is in the OFF position 2 Make electrical resistance checks for the compo nents 3 Replace any parts whose resistance re...

Page 10: ...uce risk of injury or damage to equipment conduct these electrical checks with the main disconnect OFF Zone Component Between Terminals Resistance Values ohms 1 DH Hose Aux 1232 1050 Refer to Tables 3...

Page 11: ...temperature controls Graco Factory P I and d Settings Table 5 lists the P I and d settings for standard control panels These settings are preset at the factory Use the table for reference information...

Page 12: ...4 zone control 243699 has a power disconnect switch that provides power to the temperature controls Power is not applied to the heat zones until the Heat On switch is turned on The Heat On light will...

Page 13: ...by a qualified electrician before attempting to start the system AC Heat On ON The CONTROL ON switch U is set to either the ON or AUTO position and power is being supplied to the electrical control p...

Page 14: ...the electrical disconnect on the electrical control panel 2 Open the electrical control box and locate the Ground Fault Interrupt switch GFPE The ground fault interrupt will be in a neutral position b...

Page 15: ...e the blown fuse s High Temperature Alarm lights The temperature of a heated component has gone out of range Supply unit automatically turns off power to supply unit components and air motor Unit turn...

Page 16: ...Parts 16 309213G Parts Model 243698 Control Electrical 230 240 VAC 2 Zone TI0562 TI0562 16 pin outlet connector TC107 TC114 GROUND LUG PANEL LAYOUT...

Page 17: ...Parts 309213G 17 Parts Model 243699 Control Electrical 230 240 VAC 4 Zone 2 16 pin outlet connectors TC107 TC121 TC114 TC128 CP 8 GROUND SLUG PANEL LAYOUT TI0561 TI0561...

Page 18: ...ssmann FNQ R 6 Class CC 116208 2 TC107 114 Temperature Controller 233150 2 243699 4 Zone Control 400VAC CR111 156 162 Deltrol 203028 85 3PDT SEMKO 240VAC Coil 116202 3 SSR116 123 130 137 Carlo Gavazzi...

Page 19: ...Electrical Schematics 309213G 19 Electrical Schematics 230 240 VAC 2 Zone...

Page 20: ...Electrical Schematics 20 309213G Electrical Schematics 230 240 4 Zone...

Page 21: ...Electrical Schematics 309213G 21 Electrical Schematics 230 240 4 Zone continued...

Page 22: ...Dimensions 22 309213G Dimensions Electrical Control Panel Mounting and Clearance Dimensions FIG 7...

Page 23: ...escription Specification Voltage 220 240 AC Frequency 50 60 Hz Power Phases Full Load Amps 2 zone 243695 11 0 amps 4 zone 3243699 15 5 amps Weight 2 zone 243695 5 lb 2 3 kg 4 zone 243699 55 lb 25 kg 1...

Page 24: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...