![background image](http://html1.mh-extra.com/html/graco/therm-o-flow-243698/therm-o-flow-243698_instructions-manual_2251035008.webp)
Installation
8
309213G
Installation
Connecting the Electrical
Control Panel to a Power Source
F
IG
. 3
Have
a
trained
electrician
connect
the
electrical
control
panel
(Fig.
3)
to
a
grounded
electrical
source
that
has
the
required
service
ratings:
To
connect
the
control
panel
to
the
electrical
source:
1.
Locate the opening in the control panel’s bottom
housing for the conduit that will enclose the wire
from the facility’s power source. The hole diameter
is .804” (20 mm) and includes a cord strain relief for
cable diameters from .236” (6 mm) to .472” (12
mm).
2.
Thread the wire from the power source into the
con-
trol panel housing
,
and then connect the power
source wires to the appropriate terminals on the
panel
.
See
beginning on
page
.
WARNING
ELECTRIC SHOCK HAZARD
Do not connect the electrical control panel to
a power source unless you are a trained
professional. Failure to follow standard
procedures or to observe the necessary
precautions could result in serious bodily
injury or equipment damage.
CAUTION
If power and grounding connections are not done
properly, the equipment will be damaged and the
warranty will be voided. Check the label on the
control box for the proper voltage.
AC
Panel Voltage
Hz
Phase
Full Load Amps
220/240
50/60
1
15.5A - 4-Zone
Control (243699)
11.0A - 2-Zone
Control (243698)