Start Up
3A4476E
9
Start Up
Always start with a fully charged battery.
See battery and charger information
shipped with the sprayer.
Pressure Relief Procedure
Follow the Pressure Relief
Procedure whenever you see this
symbol.
1.
Remove battery from the sprayer.
2.
Turn Prime Pump/Spray Knob down to
PRIME PUMP position to relieve
pressure.
Starting a New Job
If you are using the sprayer for the very first
time, see
Strain the Paint
Previously opened paint may contain dried
paint or other debris. To avoid priming
problems and tip clogs it is advisable to strain
the paint before using. Paint strainers are
available where paint is sold. Stretch a paint
strainer over a clean pail and pour the paint
through the strainer to capture any dried paint
and debris before spraying.
Use only oil-based (non-flammable) or
water-based materials, or non-flammable
paint thinners. Do not use materials having
flash points below 100°F (38°C).
Do not use materials which state
“FLAMMABLE” on the packaging. For
more information about your material,
request SDS from distributor or retailer.
When spraying oil-based material, use
outdoors or in a well-ventilated indoor area
with a flow of fresh air.
Keep spray area well-ventilated. Keep a
good supply of fresh air moving through the
area.
NOTICE
Your sprayer is
NOT
compatible with harsh
cleaners such as chlorine bleach. Using these
cleaners will cause damage to the sprayer.
This sprayer builds up an internal pressure of
2000 psi (14 MPa, 138 bar) during use. Follow
this Pressure Relief Procedure whenever you
stop spraying and before cleaning, checking,
servicing, or transporting equipment to prevent
serious injury.
ti26894a