background image

Parts 

12

313444E

Replacement Danger and Warning labels, tags and 
cards are available at no cost.

Ref

Part No. Description

Qty

1

562850

PUMP, EO-3 motor/timer 115V 
(models 24B219, 258301, 24R127, 
24V204, 25C264 and 258347)

1

564254

PUMP, EO-3 24V, with timer (mod-
els 258295 and 564445)

1

258294

PUMP, EO-3 230V, without timer, 
PS/LL (models 24H681, 24V531, 
26C419, 25C265, 26C521 and 
25A209)

1

24B430

PUMP, EO-3, 230V w/o timer 
(model 25A202)

1

2

TUBE, nylon 6mm OD

1

3

NUT, hex 

8

4

555456 PLUG, 1/16 NPT

2

5

558801

FITTING, elbow 1/8 NPT X 6mm 
tube

1

6

SCREW, 1/4-20 X.625 hex hd cap

4

7

SCREW, 1/4-20 X.750

2

8

SCREW, 1/4-20 X 2.25 soc hd cap 2

9

WASHER, lock

8

10

WASHER, plain

2

11

O-RING, -008 BUNA-N 70 DURO

1

12

O-RING, -010 BUNA-N 70 DURO

1

13

O-RING, -013 BUNA-N 70 DURO

1

14

O-RING, ARP-4 BUNA-N 90 
DURO

1

15

INSERT, brass, 6mm tube

2

17

558707 LABEL, warning air adj scr

1

19

16D893 BASE, Spindl-Gard

1

20

CLAMP, strain relief

1

21

CONNECTOR, tap, splice wire 
22-16 AWG (not shown)

2

22

558900

REGULATOR, assy psi switch 
spindl

1

23

557324 CLIP, half 1/4 tube stl

2

24

PLUG, dry seal 1/8 NPTF

2

25

563489 ELEMENT, filter integral 10 MIC

1

26

561031 BLOCK, inlet Spindl-Gard

1

27

561032 BLOCK, outlet Spindl-Gard

1

29

563130 BLOCK, Spindl-Gard, 0.0015 

model 24B219

2

model 258347

2

model 25C264

3

model 25C265

3

563131 BLOCK, Spindl-Gard, 0.0030

model 564445

3

model 25A202

4

model 24R127

2

model 258347

4

model 258301

6

model 25A209

4

model 26C419

2

563132 BLOCK, Spindl-Gard, 0.0050

model 258295

2

model 24V531

5

model 24H681

8

model 24V204

2

model 26C521

2

30

563940

KIT, repair, tie rod, SG-2 (models 
24B219, 258295, 24R127, 
24V204, 26C419)

1

563941

KIT, repair, tie rod, SG-6 (model 
258301 and 258347)

1

564444

KIT, repair, tie rod, SG-3 (model 
564445, 25C264, 25C265)

1

15U854

KIT, repair, tie rod, SG4 (model 
25A202 and 25A209)

1

15U855 KIT, repair, tie rod, SG-5

1

15U856

KIT, repair, tie rod, SG-8 (model 
24V531, 24H681, 26C521)

1

33

555991 LABEL, serial number

1

Ref

Part No. Description

Qty

Summary of Contents for Spindl-Gard 24B219

Page 1: ...ds greater than 250 000 DN For professional use only Models Page 2 320 psi 2 2 MPa 22 bar Maximum Working Pressure Components Electric motor driven pump 0 8 gallon 3 liter plastic reservoir Air oil dispensing module Optional programmable timer controller Important Safety Instructions Read all warnings and instructions in this manual before using the equipment Save these instructions ...

Page 2: ... cu in stroke Remote no timer Timer Included AC Models Only 24 VDC 115 VAC 230 VAC 1 2 3 4 5 6 7 8 Plugged 0 025 0 0015 0 049 0 0030 0 082 0 0050 24B219 X X X X 24H681 X X X X 24R127 X X X X 24V204 X X X X 24V531 X X X X 258295 X X X X X 258301 X X X X 258347 X X X X X 25A202 X X X X 25A209 X X X X 564445 X X X X 25C264 X X X X 25C265 X X X X X 26C419 X X X X 26C521 X X X X ...

Page 3: ... equipment daily Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children ...

Page 4: ... the instructions on the following pages Refer back to this page as needed A Purge Plug B Manual Run Reset Button C Pump ON LED D Power ON LED E Alarm LED F 1 4 18 Air Regulator Inlet NSPF G Air Oil Delivery Line H AIr Flow Adjustment Screw J Oil Pressure Gauge K Air Oil Mixing Block A B C D E J F H G K ...

Page 5: ...is manual page 13 Grounding The equipment must be grounded Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit Electrical Connections All Models 1 Verify all power to the system is disconnected 2 Remove enclosure cover from top of pump 3 Install electrical cable through connector lo...

Page 6: ...ch 0 63 cm 1 Connect incoming air line to the 1 4 18 NPSF inlet F 2 Connect air oil delivery line from the air oil mixing block K to the bearing point Air Flow Data Chart The tube size from the air oil mixing block K to the bearing is critical for proper air and oil delivery to the bearings Refer to the Air Flow Chart below for orifice and corresponding delivery tube sizes and the resulting airflo...

Page 7: ...6 bar and 0 41 MPa 4 13 bar Refer to Air Flow Chart page 6 for setting guidelines 4 Air flow is supplied on a constant basis to the air oil mixing block Adjust the air regulator to achieve the required air pressure as follows a Fill the reservoir with spindle oil b Press the manual run button B c Loosen the purge plug A on the air oil mixing block assembly K d Press the manual run button B until o...

Page 8: ...hour are required 60 12 5 set the pause time to 5 minutes NOTE Do not exceed 20 minutes Pause off time Work on Time FIG 2 and FIG 3 The Work on Time is set using the DS2 dipswitches NOTE A Work on Time of 20 seconds will normally be sufficient Prelube FIG 2 and FIG 3 J1 is used to Yes or No When set to Yes the lube cycle will immediately power up Pressure Switch FIG 2 and FIG 3 For timer models J2...

Page 9: ...ur NOTE Do not exceed 20 minutes Pause off time Monitor Time FIG 3 Set the Monitor Time to 20 seconds This will allow suffi cient time for the system pressure to rise piston distrib utors to fire and the oil pressure switch to close Cycle Switch FIG 3 Set Cycle Switch oil pressure switch transition to 1 Pressure Switch FIG 3 For timer models J2 must be set to the monitored posi tion ...

Page 10: ...he set Work Time a fault is registered causing a red Alarm LED E to light The Fault Alarm contacts to transfer The Pump ON LED C and pump turn off Other System Faults NOTE If a fault occurs press the Manual Run Rest but ton to clear the fault and restart the pump The pump will not start until the fault is cleared Startup Procedure 1 Verify the pressure regulator set point for the air oil mixing bl...

Page 11: ...Parts 313444E 11 Parts 1 3 9 14 25 19 2 23 7 15 5 30 26 29 8 27 17 6 33 20 23 ti128633 4 6 10 24 4 13 12 11 ...

Page 12: ...pindl Gard 1 20 CLAMP strain relief 1 21 CONNECTOR tap splice wire 22 16 AWG not shown 2 22 558900 REGULATOR assy psi switch spindl 1 23 557324 CLIP half 1 4 tube stl 2 24 PLUG dry seal 1 8 NPTF 2 25 563489 ELEMENT filter integral 10 MIC 1 26 561031 BLOCK inlet Spindl Gard 1 27 561032 BLOCK outlet Spindl Gard 1 29 563130 BLOCK Spindl Gard 0 0015 model 24B219 2 model 258347 2 model 25C264 3 model 2...

Page 13: ...up to 2500 SUS ISO 460 Lubrication Output 0 0015 0 0030 and 0 005 inch3 per cycle 0 025 0 049 and 0 082 cm3 per cycle Air Cleanliness Requirements 5 micron 40 F Dew point 5 micron 4 C Dew point Lubrication Filtration Requirements Filter to a minimum level recommended by the Society of Automotive Engi neers SAE which corresponds to the ISO Standard 4406 ratings specifica tions of ISO 18 14 Control ...

Page 14: ...airs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth ab...

Reviews: