background image

Warnings

308608L

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The 

exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. 

When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. 

Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this 

manual where applicable.

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.

• Do not exceed the maximum working pressure or temperature rating of the lowest rated system 

component. See 

Technical Specifications

 in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical 

Specifications

 in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 

complete information about your material, request Safety Data Sheets (SDSs) from distributor or 

retailer.

• Turn off all equipment and follow the 

Pressure Relief Procedure 

when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 

manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals and 

create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.

• Use equipment only for its intended purpose. Call your distributor for information.

• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull equipment.

• Keep children and animals away from work area.

• Comply with all applicable safety regulations.

SKIN INJECTION HAZARD

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This 

may look like just a cut, but it is a serious injury that can result in amputation. 

Get immediate surgical 

treatment.

• Do not point dispensing device at anyone or at any part of the body.

• Do not put your hand over the fluid outlet.

• Do not stop or deflect leaks with your hand, body, glove, or rag.

• Follow the 

Pressure Relief Procedure

 when you stop dispensing and before cleaning, checking, or 

servicing equipment. 

• Tighten all fluid connections before operating the equipment.

• Check hoses and couplings daily. Replace worn or damaged parts immediately.

Summary of Contents for Series D

Page 1: ...use in European explosive atmosphere locations Model 238108 Series D 1100 psi 7 6MPa 76 bar Maximum Working Pressure 180 psi 1 2 MPa 12 bar Maximum Air Input Pressure Related Manuals Important Safety...

Page 2: ...Product Life 10 Troubleshooting 11 Repair 12 Air Motor and Throat 12 Disassembly 12 Reassembly 15 Displacement Pump 16 Disassembly 16 Intake Valve 16 Displacement Pump 16 Reassembly 16 Parts 17 Displ...

Page 3: ...equipment is not in use Check equipment daily Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or mo...

Page 4: ...quipment only in well ventilated area Eliminate all ignition sources such as cigarettes and portable electric lamps Ground all equipment in the work area Keep work area free of debris including rags a...

Page 5: ...off valve E Air inlet F Ball valve for releasing collected moisture G Pump H Drain valve required J Dispensing valve model 222411 shown K Thermal relief kit required Part No 240429 L Male quick discon...

Page 6: ...ump To order a 1600 psi 11 MPa 110 bar thermal relief kit order Part No 240429 8 Install a suitable fluid hose P and dispensing valve J Four accessories are required in the system an air shut off valv...

Page 7: ...easy operator access to the pump air controls The pump must be mounted in a ver tical position See Technical Specifications page 22 for pump weight information and the Dimensions and Mounting Hole La...

Page 8: ...container and valve 3 Open the pump air regulator C slowly just until the pump is running When the pump is primed and all This equipment stays pressurized until pressure is manually relieved To help p...

Page 9: ...running too fast and check the fluid supply If the supply container is empty and air has been pumped into the lines prime the pump and lines with fluid or flush it and leave filled with a compatible...

Page 10: ...roduct s useful life dismantle and recycle it in a responsible manner Perform the Pressure Relief Procedure in your pump manual Drain and dispose of fluids according to applicable regulations Refer to...

Page 11: ...hoses valves etc Clear Damaged air motor Service air motor Exhausted fluid supply Refill and re prime or flush Continuous air exhaust Worn or damaged air motor gasket packing seal etc Service air moto...

Page 12: ...ton washer 113 7 Remove the air motor base from the vise and place the piston rod 29 flats in the vise with the air motor facing up 8 Loosen the lift ring 24 Pull up the lift ring grip the trip rod 31...

Page 13: ...the piston lugs L below the pivot pins 16 on the toggles pry up using the screwdriver handle to compress the springs on the toggle assembly M up and away from the piston lugs and remove the parts FIG...

Page 14: ...Repair 14 308608L FIG 4 Air Motor and Throat...

Page 15: ...G 4 NOTE Adjust the distance between the inlet valve poppets and the piston seat by turning the top valve nuts 21 8 Hand tighten the bottom valve nuts 21 securely 9 Align the holes in the valve nuts 2...

Page 16: ...e page 8 3 Disconnect the hoses remove the pump from its mounting and clamp the air motor base 28 in a vise horizontally by closing the vise jaws on the flange Intake Valve Refer to FIG 5 for the foll...

Page 17: ...chase separately Ref Part Description Qty 10 113345 SEAL u cup shown on page 18 1 103 101190 BALL piston metallic 1 104 101178 BALL sst 1 105 113347 PACKING o ring 1 107 113346 PACKING u cup 1 108 112...

Page 18: ...Parts 18 308608L Air Motor...

Page 19: ...inlet valve 2 18 158377 PACKING ring seal 1 19 158378 PACKING o ring 1 20 158379 PACKING o ring 1 21 160261 NUT valve 4 22 160618 WIRE lock 2 23 160623 ARM toggle 2 24 190929 RING lift 1 25 167585 SP...

Page 20: ...vertical scale on left side of the chart to read air consumption Test Conditions Pump tested with AW 32 oil at 75 F 24 C To find Fluid Outlet Pressure psi bar at a specific fluid flow gpm lpm and ope...

Page 21: ...Dimensions 308608L 21 Dimensions Model 238108 Pump Series D Mounting Hole Layout...

Page 22: ...4 5 per gallon 3 8 per liter Maximum recommended pump speed 78 cycles min 6 gpm 23 l min Recommended speed for optimum pump life 15 to 25 cycles per min Wetted Parts Piston seals polyurethane with nit...

Page 23: ...California Proposition 65 308608L 23 California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm www P65warnings ca gov...

Page 24: ...in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARR...

Reviews: