Installation
3A7939A
9
Connect Power
NOTE:
The sprayer is rated 200-240 Vac, 1 Phase, 20A,
50/60 Hz. A dedicated 20A circuit with a NEMA L6-20R
receptacle is required.
1. Before use, verify that you have the required
20-Amp circuit with a NEMA L6-20R receptacle.
WLD
WLD
=
2. Plug the power cord (Z) into the receptacle.
Extension Cords
If an extension cord is necessary, use a 12 AWG (2.5
mm
2
) or thicker cord to carry the current that the sprayer
draws. Undersized extension cords result in a drop in
line voltage and loss of power and overheating.
Select the minimum cord wire gauge based on length
according to the table below:
Make sure your extension cord is not damaged.
Install Vented Oil Cap Before
Using Equipment
The sprayer's motor gear box is shipped from the
factory pre-filled with oil. The temporary unvented cap
(PX) prevents oil leaks during shipment.
Replace the temporary unvented cap (PX) with the oil fill
cap (P) before use.
ti36317a
PX
P
Length
Gauge
mm
2
50 ft (15.24 m)
12 AWG
3.31
100 ft (30.48 m)
10 AWG
5.26
200 ft (60.96 m)
6 AWG
13.29
300 ft (91.44 m)
4 AWG
21.14