Troubleshooting
26
3A7939A
Erratic or accelerated
pump speed
Disinfectant supply is empty
Refill and prime the pump.
Clogged suction
Clean the suction tube.
Open or worn piston valve
packings
Clear the piston valve. Replace the packings.
Open or worn intake valve
Clear or service the intake valve.
Clogged gun, hose, outlet,
etc.
Clear the gun, hose, outlet, etc.
Open or worn outlet check
valve
Clear or service the outlet check valve.
Cycles or fails to hold
pressure at stall
Worn intake or piston valve
or seals
Service the pump (see your pump manual).
Poor or irregular spray
pattern
Incorrect disinfectant
pressure at gun
See your gun manual. Read the disinfectant
manufacturer’s recommendations.
Dirty, worn, or damaged
spray gun
Service the spray gun (see your spray gun manual).
Motor does not turn over
and LED is off
Over voltage (greater than
300 V)
Check the power supply.
No power to the control
board
Verify that the power supply is connected. Check the
junction box connections.
Motor does not turn over
and LED is on
Encoder fault
Cycle power. Recalibrate the encoder following the
procedure listed in your motor manual. Contact your Graco
distributor or Tech Service for more information.
Oil is leaking
Oil was over filled
Drain and refill oil as stated in
, page 23.
Drain plug is not tightened
properly
Torque to 18-23 ft-lb (25-30 N•m).
Seal cartridge o-ring missing
or damage
Replace the shaft bearing assembly. See your motor
manual.
Problem
Cause
Solution