Performance Data
3000HS Flapper Pump
Condition
10 Hz
20 Hz
30 Hz
40 Hz
50 Hz
60 Hz
Maximum fluid flow, gpm (lpm)
18.4
(69.5)
31.6
(120)
40.8
(154)
44.8
(170)
51.7
(196)
62.5
(237)
Displacement per cycle, gallons (liters) 0.69
(2.6)
0.59
(2.2)
0.51
(1.9)
0.42
(1.6)
0.39
(1.5)
0.39
(1.5)
Medium speed gear ratio pumps with gearmotor and compressor (14), (15), or
(16)
KEY
A
Power Limit Curve
B
Net Positive Suction Head Required
The shaded area is recommended for continuous
duty.
2150T FDA Pump
Frequency — Hz (Pump Speed Cycles per Minute)
Outlet
Pressure
PSI
(bar, MPa)
0
10
(0.7, 0.07)
20
(1.4, 0.14)
30
(2.1, 0.21)
40
(2.8, 0.28)
50
(3.5, 0.35)
60
(4.1, 0.41)
70
(4.8, 0.48)
80
(5.5, 0.55)
90
(6.2, 0.62)
100
(6.9, 0.69)
0
20
(76)
40
(151)
60
(227)
80
(303)
100
(379)
20
(36)
30
(54)
40
(73)
50
(91)
60
(109)
70
(127)
80
(145)
90
(163)
0
5
(1.52)
10
(3.05)
15
(4.57)
20
(6.10)
25
(7.62)
30
(9.14)
35
(10.67)
A
B
NPSHr
feet WC
(meters
WC)
Fluid Flow — gpm (lpm)
3A5132F
25