Installation
Mount the HS Pump
To avoid serious injury or death from toxic fluid or
fumes:
• Never move or lift a pump under pressure. If
dropped, the fluid section may rupture. Always
follow the
Pressure Relief Procedure, page 21
,
before moving or lifting the pump.
NOTICE
The pump is heavy. To prevent damage from
dropping, always use a lift to move the pump. Do
not use the manifolds to lift the pump. Use at least
two straps.
1. For all mountings, be sure the pump is secured
with screws through the mounting bracket.
2. Make sure the mounting surface is flat and
that the pump base doesn’t wobble. See
Dimensions (3000HS Flapper Pumps), page 31
.
NOTICE
To prevent pump damage, use all fasteners.
3. For ease of operation and service, mount the
pump so fluid inlet and fluid outlet ports are easily
accessible.
4. Attach the pump base to the mounting surface.
3A5132F
13