Troubleshooting
26
3A6884B
TSP power pack does not run at all.
Display shows
CODE 08.
Incoming voltage too low for
TSP power pack operation.
1.
Set TSP power pack to OFF and
disconnect power to TSP power
pack.
2.
Remove other equipment that uses
the same circuit.
3.
Locate a good voltage supply to
avoid damage to electronics.
TSP power pack does not run at all.
Display shows
CODE 10.
Control board is over
heating.
1.
Make sure motor air intake is not
blocked.
2.
Make sure fan is securely attached
to motor shaft.
3.
Replace control board.
4.
Replace motor.
TSP power pack does not run at all.
Display shows
CODE 12.
Excessive current protection
enabled.
Cycle power on and off.
TSP power pack does not run at all.
Display shows
CODE 15.
Motor not spinning (no
current to motor).
1.
Set TSP power pack to OFF and
disconnect power to TSP power
pack.
2.
Remove top half of shroud frame and
shroud.
3.
Set TSP power pack to OFF and spin
pump crank 1/2 turn. Restart TSP
power pack. If TSP power pack runs,
replace control board. If TSP power
pack does not run, continue to step 5.
4.
Turn power on. If code continues,
replace control board.
Problem
Cause
Solution