Repair
312063Z
29
Circuit Breaker Module
1. Turn main power OFF
. Disconnect power
supply. Turn circuit breakers on to test.
3. Using an ohmmeter, check for continuity across
circuit breaker (top to bottom). If no continuity, trip
breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a. Refer to electrical diagrams and to T
Disconnect wires and remove bad breaker.
b. Install new breaker and reconnect wires.
* Depending on model.
Table 3: Circuit Breakers, see F
Ref. Size
Component
809
50A
Hose/Transformer
Secondary Side
811
40A
Transformer
Primary
812A
25A, 40A, or
50A*
Heater A
812B
25A, 40A, or
50A*
Heater B
813
20A or 30A*
Motor/Pumps
F
IG
. 4 Circuit Breaker Module
ti9884a
812A
813
809
811
NOTE:
To reference cables and
connectors, see the electrical diagrams
and the parts drawings on pages 66-67.
812B