6. Press start button
on the engine control
module twice to start the generator. Verify
voltages are displayed on engine control module
before moving to next step.
The controller will automatically begin glow plug
warming and crank operations. Allow engine to
reach full operating speed.
Note
Engine will not start if main power switch
is in the ON position.
7. Turn main power switch ON.
The ADM will display the following screen until
communication and initialization is complete.
8. For first startup of new system, set system
settings on ADM in Setup Mode.
See
9. For first startup of new system, adjust air settings
to zero:
a.
Close the main air shutoff valve (CK).
b. Ensure all three air regulators are turned fully
counterclockwise.
58
332636C