background image

Service 

6

3A8507C

Service

After the TLM has been installed, the only additional 

maintenance or service necessary is changing the 

batteries.

Replace Batteries

1. Remove the TLM adapter from the tank.

2. Remove the four screws that keep the case 

together (F

IG

. 7).

3. Carefully pull the TLM case halves apart to access 

the battery (F

IG

. 8).

NOTE: The TLM case halves are tightly connected. Use 

caution when opening the device to prevent 

unnecessary damage.

4. Replace the 3.6V C-size battery. See 

Technical 

Specifications

, page 8, for battery information. 

Install the battery as shown in F

IG

. 9, with the 

positive end on the right. This is the clip that has 

shrink tubing on it.

5. To maintain the IP rating, make sure that the gasket 

is properly installed (F

IG

. 9).

6. Reconnect the two halves and replace the four 

screws.

WARNING

Fire and Explosion Hazard

Sparking can occur when changing batteries. Only 

replace the batteries in a non-hazardous location 

away from flammable fluids and fumes.

NOTICE

After battery placement, press the button to synchronize 

the TLM internal clock to maintain scheduled TLM 

readings.

F

IG

. 7

Screws

F

IG

. 8

F

IG

. 9

Place Gasket 

Here

Summary of Contents for Pulse 25T460

Page 1: ...can cause death or serious injury Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for t...

Page 2: ...k password 6 Click the Connect to WIFI button 7 The LED on the Pulse sensor turns green FIG 3 8 Wait approximately 20 seconds 9 The sensor flashes red or green several times Green flashes indicate tha...

Page 3: ...ss steel self tapping counter sunk screws included with kit to attach the adapter to the tank Do not over tighten 4 Attach the sensor to the adapter To form a secure seal make sure that the sensor is...

Page 4: ...ll 3 Continue with Mount Options steps 1 through 4 Operation View Data The TLM can be configured with the Pulse Level level gracopulse com to take a reading at predefined times After configuring the T...

Page 5: ...gs Out of WiFi range WiFi obstruction Ensure that the TLM is not encased in metal since this would obstruct the signal Take a manual measurement and review LEDs during the measurement Weak or dead bat...

Page 6: ...ize battery See Technical Specifications page 8 for battery information Install the battery as shown in FIG 9 with the positive end on the right This is the clip that has shrink tubing on it 5 To main...

Page 7: ...llons or liters Tank end walls must be flat they cannot be any other shape including belled Obround Tank Maximum volume 999 999 gallons or liters Tank end walls must be flat they cannot be any other s...

Page 8: ...2 GHz 2 462 GHz Maximum RF Transmit Power 18 dBm Operating Temperature Range 0 F to 122 F 17 8 C to 50 C Storage Temperature Range 0 F to 122 F 17 8 C to 50 C Batteries Li SOCl2 Size R14 3 6V C cell B...

Page 9: ...MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other re...

Page 10: ...hanges at any time without notice Original instructions This manual contains English MM 3A8507 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES...

Reviews: