Setup Mode
312776K
43
Recipe Setup Screen 5
This screen appears only if K-factor Input is set to “Rec-
ipe” in
, page 34.
K-factor A Meter
Enter the k-factor (cc/pulse) for flow meter A. This is the
amount of material that passes through the flow meter
per pulse (electrical pulse signal).
K-factor B Meter
Enter the k-factor (cc/pulse) for flow meter B.
K-factor Solvent Meter
This field only appears if Solvent Monitor in
, page 33, is set to “Meter.” Enter the k-factor
(cc/pulse) for the solvent flow meter.
Recipe Setup Screen 6
This screen appears only if Flow Rate Monitor is set to
“On” in
on page 35.
Flow Rate Monitor
Select the desired flow rate monitoring (Off, Warning, or
Alarm).
Low Flow Limit
Enter the low flow rate limit (1 to 3999 cc/min).
High Flow Limit
Enter the high flow rate limit (1 to 3999 cc/min).
F
IG
. 43. Recipe Setup Screen 5
F
IG
. 44. Recipe Setup Screen 6