Electrical
3A1163A
21
Electrical
Requirements
NOTE: All options ordered on the ProControl system are
electrically tested at the factory.
The ProControl operates with 85-250 VAC, 50/60 Hz
input power, with a maximum of 2 amp current draw.
The power supply circuit must be protected with a 15
amp maximum circuit breaker.
Not included with system:
•
Power supply cord compatible to your local power
configuration. Wire gauge size must be 8-14 AWG.
•
The input power access port
is 22.4 mm
(0.88 in.) diameter. It accepts a bulkhead strain
relief fitting or conduit. See F
IG
. 10.
Connect Main Power
1.
Provide power to the EasyKey. Install a bulkhead
strain relief or conduit bulkhead through the
EasyKey port
. See F
IG
. 10.
2.
See F
IG
. 9 and the System Electrical Schematic
on page 30 for the L1, N, and ground wiring connec-
tions inside the EasyKey.
3.
Ground the EasyKey to a true earth ground. See
Grounding, page 27.
All electrical wiring must be completed by a qualified
electrician and comply with all local codes and regula-
tions.
Enclose all cables routed in the spray booth and high
traffic areas in conduit to prevent damage from paint,
solvent, and traffic.
F
IG
. 9. Main Power Connection
TI13349a
Input Power
Terminal Block