Manifold Parts
03226
Front View
Back View
106
111
110
102
104
103
112
117
118
106
113
107
115
105
108
121
101
03462
109
122
123
37
Ref. 101
114
116
117
118
Apply low strength
(purple) Loctite
r
or an
equivalent sealant to the threads.
Press fit the spring (105)
Tighten the fitting until the hex bottoms
against the manifold.
This fitting (113) has left-hand threads.
Install the kV cap (111) flush to the outside
surface.
Concave side of the disk (114) faces toward
the manifold.
Replace the spring (122) every 300,000
cycles.
An optional fiber optic fitting (37) is included
with the gun assembly; see page 41 or 43.
Remove the plug (115) and install the fitting
(37) if a kV display is being used.