Maintenance
Check for Fluid Leakage (See Fig. 15)
FIRE AND EXPLOSION HAZARD
If any fluid leakage from the gun is de-
tected, stop spraying
immediately!
Fluid leakage into the gun shroud could
cause fire or explosion and result in
serious injury and property damage.
WARNING
PRESSURIZED EQUIPMENT
To reduce the risk of a serious injury,
follow the
Pressure Relief Procedure
on page 17 when you stop spraying and
whenever you are instructed to relieve the pres-
sure.
WARNING
During operation, periodically check the manifold
exhaust tube (YY) and both ends of the gun shroud
(ZZ) for the presence of fluid. Fluid in these areas
would indicate fluid leakage into the shroud, which
could be caused by leaks at the fluid tube connections
or fluid packing leakage.
If fluid is seen in any of these areas, stop spraying
immediately!
Relieve the system pressure, then
remove the gun for repair.
Fig. 15
Check for signs of fluid leakage
where indicated by arrows.
03445
YY
ZZ
YY
03446
ZZ
Manifold Back View