![Graco PRO 5500sc Instruction Manual Download Page 26](http://html1.mh-extra.com/html/graco/pro-5500sc/pro-5500sc_instruction-manual_2252672026.webp)
Troubleshooting
Electrical Troubleshooting
PROBLEM
CAUSE
SOLUTION
Poor wrap-around
The turbine air is not on.
The distance between the gun and
workpiece is incorrect.
The parts are poorly grounded.
Booth exhaust velocity is too high.
The atomizing air pressure is too high.
The fluid pressure is too high.
The fluid viscosity is not right for electros-
tatic spray.
The voltage output is too low.
The turbine alternator is not operating.
The gun resistance is faulty.
Fluid leaks from the fluid rod packing and
causes a short.
The turbine alternator is faulty.
The kV switch is stuck on low.
Turn on the turbine air.
Adjust the spraying distance to 8 to 12
inches (203 to 305 mm).
Clean the workpiece hangers; check for
proper grounding on the conveyor or track.
Reduce the exhaust velocity within the
code limits.
Reduce the atomizing air pressure.
Reduce the fluid pressure.
Check with the supplier for proper fluid
viscosity for electrostatic spray.
Check the possible causes listed below.
Check the air supply to the gun.
Check the gun resistance; see page 27.
Clean the fluid rod cavity, replace the
packing; see page 32.
Be sure the plug is in place on the back of
the turbine alternator housing; remove
and test the turbine alternator; see
page 37.
Check the switch actuation; replace the
kV switch if necessary.
The operator gets a shock
The operator is not properly grounded or
is near an ungrounded object.
The gun is not properly grounded.
Be sure the floor and the operator are
properly grounded; see
Ground the Sys-
tem, page 14.
See
Check the Electrical Grounding,
page 15.
The operator gets a shock when
touching the workpiece
The workpiece is not properly grounded.
Clean the workpiece hangers; check for
proper grounding on the conveyor or
track.
No or low voltage output reading on
the gun ES (kV) display module
The fiber optic cable or connection is
damaged.
The turbine air is not on.
Check the cables and connections;
replace the parts if they are damaged.
Turn on the turbine air.
See other causes under
Problem – Poor
wrap-around, above.
Refer also to the Graco ES display mod-
ule manual 308–265.