Technical Data
3A1450B
19
Technical Data
Air inlet size: 1/2 npt(f)
Fluid inlet size: 1-1/2 npt(f)
Fluid outlet size: 1 npt(f)
Wetted parts: See Lower manual 3A0539.
Sound Pressure Levels (measured at 1 meter from unit)
Sound Power Levels (tested in accordance with ISO 9614-2)
NOTE: See President motor manual 306982 for sound data at higher air pressures.
Model
Maximum Fluid
Working Pressure
psi (MPa, bar)
Maximum
Air Input Pressure
psi (MPa, bar)
Air Consumption
Fluid Flow at 60
cycles per minute
gpm (lpm)
Output per Cycle
gal. (cc)
Maximum
Fluid
Temperature
Rating
°F (°C)
24H627
460 (3.2, 32.0)
150 (1.0, 10)
See Performance
Charts
9.6 (36.4)
0.16 (610)
150° (66°)
24H628
460 (3.2, 32.0)
150 (1.0, 10)
9.6 (36.4)
0.16 (610)
24H629
460 (3.2, 32.0)
180 (1.2, 12)
14.1 (53.5)
0.23 (890)
24H997
460 (3.2, 32.0)
180 (1.2, 12)
14.1 (53.5)
0.23 (890)
24J074
460 (3.2, 32.0)
150 (1.0, 10)
9.6 (36.4)
0.16 (610)
24J075
460 (3.2, 32.0)
150 (1.0, 10)
9.6 (36.4)
0.16 (610)
Air Motor
Input Air Pressures at 15 cycles per minute
40 psi (0.28 MPa, 2.8 bar) 70 psi (0.48 MPa, 4.8 bar) 100 psi (0.7 MPa, 7.0 bar)
President
73.6 dB(A)
78.3 dB(A)
80.9 dB(A)
Air Motor
Input Air Pressures at 15 cycles per minute
40 psi (0.28 MPa, 2.8 bar) 70 psi (0.48 MPa, 4.8 bar) 100 psi (0.7 MPa, 7.0 bar)
President
87.4 dB(A)
92.1 dB(A)
94.6 dB(A)
Summary of Contents for President 24H627