310531
20
Loading Material into PrecisionFlo Module
Setting the Scale Factor for Pressure Sensors
(continued)
5.
Enter the information:
a.
Key in the 4-digit maximum Vdc, (the Preci-
sionFlo software automatically enters the
decimal point) and press
[ENTER]
.
b.
Use the
↑
arrow to move to the maximum
pressure field.
c.
Key in the maximum pressure, and press
[ENTER]
.
d.
Use the
↑
arrow to move to the minimum Vdc
field.
e.
Key in the 4-digit minimum Vdc, (the Preci-
sionFlo software automatically enters the
decimal point) and press
[ENTER]
.
f.
Use the
↑
arrow to move to the minimum
pressure field.
g.
Key in the minimum pressure, and press
[ENTER]
.
6.
Press either
[BACK]
to return to the PROTECTED
SETUP menu or
[HOME]
to return to the HOME
screen.
7.
To set sensor pressure limits, go to the next proce-
dure.
Setting Pressure Sensor Limits
Set pressure limits, according to material, hose
lengths, and dispense device configurations used. The
PrecisionFlo module uses the pressure limits to trigger
corresponding low and high pressure warning faults
(see page 48).
CAUTION
Do not set the pressure above maximum psi of your
pressure sensor. Attempting to operate the Preci-
sionFlo module with a pressure above the maximum
psi could result in damage to the equipment.
Setting the Outlet Pressure Limit
Enter 3500 for the high pressure limit and 0 for the low
pressure limit.
1.
On the control pendant:
HOME
SETUP
Outlet Pressure Limit
2.
Key in the High Pressure Limit, then press
[ENTER]
.
3.
Move the cursor to the next line. Key in the Low
Pressure Limit and press
[ENTER]
.
4.
Press
[BACK]
to return to the SETUP screen.
Setting the Inlet Pressure Limit
If you have an inlet pressure sensor, you must first
determine the maximum and minimum pressure limits.
If you do not have an inlet pressure sensor, enter 0 for
the high and low pressure limits.
1.
On the control pendant:
HOME
SETUP
Inlet Pressure Limit
2.
Key in the High Pressure Limit, then press
[ENTER]
.
3.
Move the cursor to the next line. Key in the Low
Pressure Limit and press
[ENTER]
.
4.
Press
[BACK]
to return to the SETUP screen.
Setting the Tip Pressure Limit
If you have a tip pressure sensor, you must first deter-
mine the maximum and minimum pressure limits. If
you do not have a tip pressure sensor, enter 0 for the
high and low pressure limits.
1.
On the control pendant:
HOME
SETUP
Tip Pressure Limit
2.
Key in the High Pressure Limit, then press
[ENTER]
.
3.
Move the cursor to the next line. Key in the Low
Pressure Limit and press
[ENTER]
.
4.
Press
[BACK]
to return to the SETUP screen.