6
309377
Installation
10. Thread the sealing nut (5c, 6c, or 7c) onto the
extension (5a) or street elbow (6d or 7d), thread
the extension or elbow in at least three full turns,
position it for proper alignment, and tighten the
sealing nut. The PTFE seal on the sealing nut
must face the valve housing. See Fig. 4.
NOTE: The flexible extension (6a) can also be
threaded directly into the meter outlet without the
street elbow or sealing nut. See the note in the
Parts Drawing on page 19.
11. Thread the new nozzle (5b, 6b, or 7b) onto the
extension, and, with an open-end adjustable
wrench, tighten it firmly. See Fig. 4.
NOTE: Only tighten the nozzle with the wrench
on the flats of the nozzle bushing. Do not disas-
semble the bushing from the nozzle. Disas-
sembly will affect the performance of the nozzle.
WARNING
Do not use Graco’s old nozzle (Part No. 203655) or
any other manual shut-off nozzle on the PM5
extension. You must use the new automatic nozzle
that is provided with the PM5, or the meter could
be damaged. Do not use any sealant material.
12. Open all dispense position shut-off valves, and
start the pump to pressurize the system. See the
Operation section for proper operation of meter.
13. To ensure dispensing accuracy, purge all air from
the fluid lines and dispense valve before you use
it. Set the system flow to the desired flow rate,
which is typically 1.5 gpm. Do not exceed a 5-gpm
flow rate.
3
hose fitting
Slide onto
hose before
connecting.
Fig. 3
4
TI0328
hose
5c
4
5a
5b
Model shown has
75
_
bend rigid
extension
Fig. 4
Nozzle is not serviceable.
nozzle bushing
TI0327
Grounding
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, ground all system
components according to local and national electrical
codes. Refer to the user manuals for the pump and
other system components, and ground the following:
D
Pump: Follow the manufacturer’s recommend-
ations.
D
Air and Fluid hoses: Use only grounded hoses.
D
Air compressor: Follow the manufacturer’s recom-
mendations.
D
Fluid supply container: Follow the local code.
To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
valve firmly to the side of a grounded metal pail, then
trigger the valve.