PROBLEM
CAUSE
SOLUTION
Pump does not operate, or no fluid flow.
Loose or broken pump parts.
Disassemble, check, repair.
Restricted line or inadequate air supply.
Clear, increase.
Exhausted fluid supply.
Refill and prime.
Clogged fluid hoses.
Clean, or replace.
Damaged air motor.
Repair.
Pump operates, but output is low.
Insufficient air supply.
Increase.
Exhausted fluid supply.
Refill and prime.
Obstructed gun or dispensing valve.
Clear.
Packing retainer needs adjustment.
Loosen or tighten screws as necessary.
Damaged fluid pump packings.
Replace.
Held open or worn piston intake valve.
Repair.
Erratic or accelerated operation.
Exhausted fluid supply.
Refill and prime.
Fluid intake or piston valve worn.
Repair.